Test–retest reliability of mandibular morphology measurements on cone-beam computed tomography-synthesized cephalograms with random head positioning errors

机译:具有随机头定位误差的锥形光束计算机断层扫描结构综合性头部测量的测试 - 保持性可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background Cephalometric radiography has been used for orthodontic and surgical treatment planning and assessment, and for quantifying mandibular growth. However, it remains unclear how head positioning errors and the level of examiner experience affect the reliability of such morphometric measurements. The current study aimed to bridge the gap by determining the intra-, inter-rater, and inter-session reliability of measurements of mandibular morphology with random head positioning errors as measured by a junior and a senior dentist. Methods Cone-beam computed tomography data of twelve mandibles were obtained with each rotated randomly away from the neutral position within the range of +3 and −3° along each of the anatomical axes to simulate six imaging trials. A synthetic cephalogram for each trial was obtained via a digitally reconstructed radiography (DRR) technique and eleven landmarks for twelve morphological parameters on the cephalogram were identified manually six times by a junior and a senior dentist. The procedure was repeated on another day within 5 days. Test–retest reliability was assessed in terms of an intra-class correlation coefficient (ICC) using a two-way mixed-effects model. Results Good to very good intra-rater (senior: ICC > 0.92; junior: ICC > 0.78), inter-rater (ICC > 0.70 for most parameters) and inter-session reliability (senior: ICC > 0.84; junior: ICC > 0.62) were found. Bland & Altman plots of inter-rater comparisons show that there were systematical biases between the examiners on most parameters, except for the distance between Gonion and Pogonion. Conclusions The current results suggest that good to very good intra-rater, inter-rater and inter-session reliability can be achieved for most parameters with randomized head positioning errors; higher inter-session reliability can be achieved by more experienced examiners; and that long-term monitoring of mandibular growth based on cephalographic measurements should be made by the same more experienced examiner. The current DRR-based approach can be used to evaluate individual factors that affect the morphological measurements.
机译:摘要背景头部射线照相已被用于正畸和外科治疗计划和评估,以及定量下颌生长。然而,它仍然尚不清楚头部定位误差和检查器经验的程度如何影响这种形态测量测量的可靠性。目前的研究旨在通过确定初中的帧间性阶段和会话间的可靠性来弥合差距,随着初级和高级牙医测量的随机头定位误差。方法沿着每个解剖轴随机旋转,每个旋转从中性位置随机旋转,从中立的位置旋转,从中立的位置旋转,从而沿着每个解剖轴来模拟六个成像试验。通过数字重建的射线照相(DRR)技术获得每次试验的合成头像,并通过初级和高级牙医手动识别头颅图中的十二个形态参数的11个地标。该程序在5天内在另一天重复。根据使用双向混合效应模型的类内相关系数(ICC)来评估测试 - 保持可靠性。结果良好的速度非常好(高级:ICC> 0.92;初级:ICC> 0.78),税率(ICC> 0.70为大多数参数)和会间间可靠性(高级:ICC> 0.84;初级:ICC> 0.62 ) 被找到。帧间间比较的平坦和奥特曼图表明,在大多数参数之间存在对审查员之间的系统偏见,除了巨头和尖峰之间的距离。结论目前的结果表明,对于具有随机头定位误差的大多数参数,可以实现良好的额外rater,帧间间可靠性;通过更有经验的审查员可以实现更高的会话间可靠性;并且,基于头部测量的颌骨增长的长期监测应由相同的经验丰富的审查员进行。基于DRR的方法可用于评估影响形态学测量的单个因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号