首页> 外文OA文献 >DETERMINATION OF INSULATION PARAMETERS OF CURRENT TRANSFORMERS AT MULTIPLE MEASUREMENTS IN MONITORING SYSTEMS UNDER WORKING VOLTAGE
【2h】

DETERMINATION OF INSULATION PARAMETERS OF CURRENT TRANSFORMERS AT MULTIPLE MEASUREMENTS IN MONITORING SYSTEMS UNDER WORKING VOLTAGE

机译:工作电压下监测系统多测量电流互感器绝缘参数的确定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Features of the data processing procedures of multiple measurements of the dielectric loss tangent of the high-voltage insulation, which are based on the comparison method, were considered. Three procedures were compared: the one procedure uses an assignment of a particular standard object for comparison, and two procedures don't use assignments of the special standard objects. Expressions of methodical errors of studied procedures were obtained. Analysis and calculations, which use the obtained expressions were made. Evaluations showed that an influence of a change of the tangent of dielectric loss of one from the monitoring objects on results of estimation of the tangents of other monitoring objects is the distinctive feature of the procedures without assignment of the standard object. Errors of these procedures more than errors of the traditional procedure, with assignment of the standard object. The study demonstrated that procedures without assignment of standard objects lead to difficultly predictable methodological errors, which hinder to estimate the actual value of the loss tangent and to estimate outcomes of the monitoring, by means comparing with allowable values. Moreover, the decrease of estimations of loss tangents of all objects, as a result of occurrence of at least one the object with strongly bad parameters, hides occurrence of other unsuccessful objects with smaller deviations and makes difficult recognition of such deviations at early stages. Improvements in processing techniques which reduce earlier specified errors and reduce the amount of measurements are proposed. The study results are useful in monitoring and diagnostic of basic insulation of current transformers or high-voltage bushings.
机译:考虑了基于比较方法的高压绝缘的介电损耗的多测量数据处理程序的特征。比较了三个程序:一个过程使用特定标准对象的分配进行比较,两种过程不使用特殊标准对象的分配。获得了研究程序的有条件误差的表达。使用所获得的表达的分析和计算。评估表明,从监测对象对其他监测对象的切线结果的监测对象的介电损失变化的影响是没有分配标准对象的程序的独特特征。这些过程的错误超过传统过程的错误,具有标准对象的分配。该研究表明,没有分配标准物体的程序导致难以预测的方法误差,这阻碍了估计切线的实际值和估计监测的结果,通过与允许值进行比较。此外,由于至少一个具有强烈差的对象的物体的发生的结果,估计所有物体的损失切线的估计减少,掩盖具有较小偏差的其他不成功物体的发生并且在早期阶段难以识别这种偏差。提出了提出减少预先指定误差并减少测量量的处理技术的改进。该研究结果可用于监测和诊断电流变压器或高压衬套的基本绝缘。

著录项

  • 作者

    V. K. Beliaev; H. N. Panenko;

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng;rus;ukr
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号