首页> 外文OA文献 >Rhizon sampler alteration of deep ocean sediment interstitial water samples, as indicated by chloride concentration and oxygen and hydrogen isotopes
【2h】

Rhizon sampler alteration of deep ocean sediment interstitial water samples, as indicated by chloride concentration and oxygen and hydrogen isotopes

机译:根际采样器对深海沉积物间隙水样品的改变,如氯化物浓度,氧和氢同位素所示

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Despite their potential to inform past ocean salinity, δ^(18)O, and temperature, high-resolution depth profiles of interstitial water chloride concentration and hydrogen and oxygen isotopes exist in very few locations. One of the primary limitations to the recovery of these depth profiles is that traditional interstitial water sampling requires 5–10 cm whole rounds of the sediment core, which has the potential to interfere with stratigraphic continuity. The Rhizon sampler, a nondestructive tool developed for terrestrial sediment interstitial water extraction, has been proposed for efficient and nondestructive sampling of ocean sediment pore waters. However, there exists little documentation on the reliability and performance of Rhizon samplers in deep ocean sediments, particularly in regard to their effect on chloride concentration and oxygen and hydrogen isotopic measurements. We perform an intercomparison of chloride concentration and oxygen and hydrogen isotopic composition in samples taken using traditional squeezing versus those taken with Rhizon samplers. We find that samples taken with Rhizons have positive biases in both chloride concentration and stable isotopic ratios relative to those taken by squeezing water from sediments in a hydraulic press. The measured offsets between Rhizon and squeeze samples are consistent with a combination of absorption by and diffusive fractionation through the hydrophilic membrane of the Rhizon sampler. These results suggest caution is needed when using Rhizons for sampling interstitial waters in any research of processes that leave a small signal-to-noise ratio in dissolved concentrations or isotope ratios.
机译:尽管它们有可能告知过去的海洋盐度,δ^(18)O和温度,但在极少数位置存在间隙水氯化物浓度以及氢和氧同位素的高分辨率深度剖面。恢复这些深度剖面的主要限制之一是传统的间隙水采样需要整个沉积岩心5–10 cm,这可能会干扰地层连续性。 Rhizon采样器是为陆地沉积物间隙水提取而开发的一种非破坏性工具,已被建议用于海洋沉积物孔隙水的高效和非破坏性采样。但是,关于Rhizon采样器在深海沉积物中的可靠性和性能的文献很少,特别是关于它们对氯化物浓度以及氧和氢同位素测量的影响。我们比较了使用传统挤压和Rhizon采样器采集的样品中氯离子浓度,氧和氢同位素组成的对比。我们发现,相对于在水压机中从沉积物中挤出水而获得的样品,用Rhizons采集的样品在氯化物浓度和稳定的同位素比率方面均具有正偏差。在Rhizon和挤压样品之间测得的偏移与通过Rhizon采样器的亲水膜进行的吸收和扩散分馏相结合。这些结果表明,在任何对溶解浓度或同位素比信噪比较小的过程的研究中,当使用Rhizons采样间隙水时,都需要谨慎行事。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号