首页> 外文OA文献 >Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series
【2h】

Annual measured and simulated thermal performance analysis of a hybrid solar district heating plant with flat plate collectors and parabolic trough collectors in series

机译:串联收集器和抛物线收集器的混合太阳能区供热厂的年测量和模拟热性能分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Flat plate collectors have relatively low efficiency at the typical supply temperatures of district heating networks (70–95 °C). Parabolic trough collectors retain their high efficiency at these temperatures. To maximize the advantages of flat plate collectors and parabolic trough collectors in large solar heating plants for a district heating network, a hybrid solar collector field with 5960 m flat plate collectors and 4039 m parabolic trough collectors in series was constructed in Taars, Denmark. The design principle is that the flat plate collectors preheat the return water from the district heating network to about 70 °C and then the parabolic trough collectors would heat the preheated water to the required supply temperature of the district heating network. Annual measured and simulated thermal performances of both the parabolic trough collector field and the flat plate collector field are presented in this paper. The thermal performance of both collector fields with weather data of a Design Reference Year was simulated to have a whole understanding of the application of both collectors under Danish climate conditions as well. These results not only can provide a design basis for this type of hybrid solar district heating plants with flat plate collectors and parabolic trough collectors in the Nordic region, but also introduce a novel design concept of solar district heating plants to other high solar radiation areas.
机译:平板收集器在区域供热网络(70-95°C)的典型供应温度下具有相对较低的效率。抛物线槽收集器在这些温度下保持其高效率。为了最大限度地提高平板收集器和抛物线槽收集器在大型太阳能加热设备中为区域供热网络,一个具有5960米平板收集器的混合太阳能收集器领域,并在丹麦淘川建造了4039米抛物线收集器。设计原则是平板收集器将返回水从区域供热网络预热至约70°C,然后抛物线槽收集器将预热水加热到区域供热网络所需的供应温度。本文介绍了抛物线槽集电磁场和平板集电极场的年度测量和模拟热性能。模拟了设计参考年度天气数据的收集器领域的热性能,以完全了解丹麦气候条件下的两个收藏家的应用。这些结果不仅能提供这种类型的混合型太阳能集中供热厂的与平板集热器和北欧地区抛物面槽式收集器设计基础,但也引入了太阳能集中供热厂的新颖的设计理念,以其他高太阳辐射的区域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号