This study presents an estimate of the probability that a single earthquake could causesimultaneous operational failure of geographically disperse data centers operated by aCalifornia utility. Three facilities are considered: a grid control facility (denoted herein byGCF), a data processing facility (DPF), and a backup data facility (BDF) that can performthe functions of either GCF or DPF, should either be rendered inoperative. This studyestimates two probabilities: (1) that within the next 5 years a single earthquake could renderboth the grid control and backup facilities inoperative; and (2) that within the next 5 years asingle earthquake could render both the data processing and backup facilities inoperative.The work was performed by researchers at the California Institute of Technology inPasadena, CA, in collaboration with researchers at the United States Geological Survey inPasadena, CA and Golden, CO. Caltech designed and directed the research, examined theseismic vulnerability of the three sites, and quantified the two probabilities desired. TheUSGS performed the hazard analysis.
机译:这项研究提出了一次地震可能导致由加州公用事业公司运营的地理分散数据中心同时运行故障的可能性的估计。考虑了以下三种功能:可以执行GCF或DPF功能的网格控制功能(此处由GCF表示),数据处理功能(DPF)和备份数据功能(BDF)。这项研究估计了两种可能性:(1)在未来5年内,一次地震可能会使电网控制和备用设施均无法使用; (2)未来5年内,一次地震可能会使数据处理和备份设施无法正常工作。这项工作是由位于加利福尼亚州帕萨迪纳市的加利福尼亚理工学院的研究人员与位于美国帕萨迪纳市的美国地质调查局的研究人员合作完成的,加州和Golden,CO。Caltech设计并指导了这项研究,检查了这三个地点的地震脆弱性,并量化了所需的两个概率。 USGS进行了危害分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号