首页> 外文OA文献 >Radiation Dose Calculations for a Hypothetical Accident in Xianning Nuclear Power Plant
【2h】

Radiation Dose Calculations for a Hypothetical Accident in Xianning Nuclear Power Plant

机译:咸宁核电站假设事故的辐射剂量计算

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Atmospheric dispersion modeling and radiation dose calculations have been performed for a hypothetical AP1000 SGTR accident by HotSpot code 3.03. TEDE, the respiratory time-integrated air concentration, and the ground deposition are calculated for various atmospheric stability classes, Pasquill stability categories A–F with site-specific averaged meteorological conditions. The results indicate that the maximum plume centerline ground deposition value of 1.2E+2 kBq/m2 occurred at about 1.4 km and the maximum TEDE value of 1.41E-05 Sv occurred at 1.4 km from the reactor. It is still far below the annual regulatory limits of 1 mSv for the public as set in IAEA Safety Report Series number 115. The released radionuclides might be transported to long distances but will not have any harmful effect on the public.
机译:通过热点代码3.03进行了大气分散建模和辐射剂量计算,对假设的AP1000 SGTR事故进行了事故。针对各种大气稳定性等级计算,呼吸时间集成空气浓度和地沉积,鼠颈稳定性类别A-F具有特异性平均的气象条件。结果表明,1.2E + 2 kBq / m2的最大羽流中心线接地沉积值发生在约1.4 km,并距离反应器1.41e-05 sv的最大裁度值为1.41e-05 sv。仍远远低于公众的1 MSV的年度监管限值,如原子能机构安全报告系列号码115.释放的放射性核素可以长途跋涉,但不会对公众产生任何有害影响。