Interpretations of results from hydraulic modeling of thermal outfall diffusers for the San Onofre Nuclear Power Plant

机译:对San Onofre核电站热排污扩散器的水力模型结果的解释

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

This report presents and interpretation of results obtained during the hydraulic model study previously documented in "Hydraulic Modeling of Thermal Outfall Diffusers for the San Onofre Nuclear Power Plant" which described the hydraulic laboratory studies conducted to investigate outfall configurations for the thermal discharge from proposed Units 2 and 3 at the San Onofre Nuclear Generating Station, jointly owned by the Southern California Edison Company and San Diego Gas and Electric Company. ududA number of different experimental investigations were performed to develop the conceptual design for the new Units 2 and 3 discharge diffusers. The primary reason for the investigations was the new California thermal standards (essentially ambient temperature increment less than 4°F), which in effect precluded the use of shoreline or single outlet discharges for new units and necessitated the use of multiport diffusers. ududThe result of the investigations of different diffuser concepts was the establishment of a preliminary design for the discharge structures for Units 2 and 3, each consisting of a diffuser 2500 ft long containing 76 discharge nozzles with a nominal discharge velocity of 13 ft/sec. This preliminary design was later modified somewhat by the engineers of the Southern California Edison Company (SCE) in consideration of other factors such as structural requirements, cost, construction problems, and more accurate bathymetric details at the site. As a result the final design for each diffuser contains 63 discharge ports of diameters varying from 21.85 to 23.9 inches. The discharge ports are nozzle-riser assemblies at alternate angles of ±25° with respect to the longitudinal axis of the diffuser and 20° up from horizontal. The nozzles are positioned approximately 6 ft from the ocean bottom. The diffusers are aligned perpendicular to shore and extend from approximately 3500 ft to 8500 ft offshore. ududThe performance of the final diffuser design was evaluated in a series of confirming tests. The major results will be summarized and discussed in section 3 of this report. ududSections 3 and 4 will also include projections and elaborations on several aspects of the diffuser performance to be expected in the prototype. The possible interactions of the proposed diffuser operation with existing site factors such as ocean currents, water temperature, heat losses, and the existing power plant (Unit 1) will also be discussed in section 4.
机译:本报告介绍并解释了先前在“ San Onofre核电站热排污扩散器的液压建模”中记录的水力学模型研究期间获得的结果,该论文描述了为研究拟议2号机组的热排污口构造而进行的水力实验室研究3号位于由南加州爱迪生公司和圣地亚哥天然气和电力公司共同拥有的San Onofre核电站。 ud ud进行了许多不同的实验研究,以开发新的2号和3号单元排放扩散器的概念设计。进行调查的主要原因是新的加利福尼亚热标准(本质上环境温度增量低于4°F),这实际上使新设备无法使用海岸线或单出口排放,因此必须使用多端口扩散器。研究不同扩散器概念的结果是为2号和3号机组的排放结构建立了初步设计,每个结构均由2500英尺长的扩散器组成,包含76个排放喷嘴,额定排放速度为13 ft /秒此初步设计后来由南加州爱迪生公司(SCE)的工程师进行了一些修改,考虑到其他因素,例如结构要求,成本,施工问题以及现场更精确的测深。结果,每个扩散器的最终设计包含63个直径从21.85到23.9英寸不等的排出口。排出口是喷嘴-提升器组件,相对于扩散器的纵向轴线成±25°的交替角度,与水平方向成20°的交替角度。喷嘴的位置距海底约6英尺。扩散器垂直于海岸对齐,从大约3500英尺延伸到近海的8500英尺。 ud ud通过一系列确认测试评估了最终扩散器设计的性能。主要结果将在本报告的第3节中进行总结和讨论。 ud ud第3节和第4节还将包括对原型中预期的扩散器性能的几个方面的预测和阐述。拟议的扩压器运行与现有站点因素(例如洋流,水温,热损失和现有发电厂(第1单元))之间可能的相互作用也将在第4节中讨论。

著录项

  • 作者

    List E. J.; Koh R. C. Y.;

  • 作者单位
  • 年度 1974
  • 总页数
  • 原文格式 PDF
  • 正文语种 {"code":"en","name":"English","id":9}