Abstract Background Hallux valgus disease is a common deformity of the forefoot. There are currently more than 100 surgical approaches for operative treatment. Because hypermobility of the first tarsometatarsal joint is considered to be causal for hallux valgus disease, fusion of the tarsometatarsal joint is an upcoming surgical procedure. Despite the development of new and increasingly stable fixation devices like different locking plates, malunion rates have been reported in 5 to 15% of cases. Methods Biomechanical comparison of three commonly used fixation devices (a dorsal locking plate, a plantar locking plate, and an intramedullary fixation device) was performed by weight-bearing simulation tests on synthetic bones. Initial compression force and stiffness during simulation of postoperative weight-bearing were analysed. Results Fixation of the first tarsometatarsal joint with the plantar plate combination demonstrated a higher stiffness compared to fixation with the intramedullary implant or the medial locking plate. The intramedullary device provided the highest initial compression force. Failure was detected in the following ranking: (1) the angle-stable intramedullary fixation device, (2) the medial located plate, and (3) the plantar locking plate. Conclusion The intramedullary device demonstrated the highest initial compression force of the three tested implants. The plantar locking plate showed the best overall stability during weight-bearing simulation. Further clinical research is necessary to analyse if the intramedullary fixation device needs a longer period of non-weight-bearing to reach a better non-union rate compared to the plantar locking plate.
机译:摘要背景拇外翻疾病是前掌的常见畸形。目前有100多种手术治疗方法。由于第一跖跗关节的过度活动被认为是对于外翻疾病的因果,跗跖关节的融合是即将到来的外科手术。尽管发展了新的且越来越稳定的固定装置,如不同的锁定板,但患者的5%至15%报告了羊驼率。方法采用合成骨的负载模拟试验进行三种常用固定装置(背锁板,跖锁板和髓内固定装置)的生物力学比较。分析了术后重轴承模拟期间的初始压缩力和刚度。结果与跖叶板组合的第一个Tarsometarsal关节固定相比,与髓内植入物或内侧锁定板的固定相比表现出更高的刚度。髓内装置提供了最高的初始压缩力。在下面的排名中检测到失败:(1)角度稳定的髓内固定装置,(2)内侧位的板,和(3)跖锁板。结论髓内装置证明了三种测试植入物的最高初始压缩力。跖锁板在负载模拟期间显示出最佳的整体稳定性。如果髓内固定装置需要更长的非重量轴承,则需要进一步临床研究,以达到与跖锁板相比更好的非联合速率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号