首页> 外文OA文献 >Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: A systematic review and meta-analysis
【2h】

Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: A systematic review and meta-analysis

机译:支撑下颌覆盖植入物周围边缘骨质损失的立即和常规装载方案的比较:系统评价和荟萃分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Summary: Purpose: To compare marginal bone level changes (MBLCs) of immediately- and conventionally-loaded implants supporting a mandibular implant overdenture (IOD). Materials and methods: Both electronic (MEDLINE, PubMed, and The Cochrane Library) and manual searches were conducted for all relevant studies published from 1 January 2000 to 1 November, 2017. Randomized controlled trials (RCTs) and prospective studies with a minimum follow-up of 12 months were selected. Studies which utilized implants narrower than 3 mm were excluded from analysis. Results: Four studies met the criteria, with two evaluating horizontal bone loss. There were 70 patients in the test group (immediate loading) and 60 in the control group (conventional loading). Follow-up lasted 6–36 months, with MBLCs being interpreted from standardized periapical x-rays, panoramics or cone beam computed tomography. Each patient was given 2–3 implants.After 6 and 12 months, the differences in MBLCs were 0.04 mm (95% CI: −0.21, 0.29) and 0. 00 mm (95% CI: −0.35, 0.36) respectively. Subgroup analysis of RCTs with 2 implants revealed group differences in MBLCs as 0.13 mm (95% CI: −0.22, 0.48) and that in horizontal bone loss as 0.04 mm (95% CI: −0.02, 0.10). No statistically significant differences were identified (p > 0.05). Conclusion: The MBLCs of immediately-loaded implants for mandibular IODs seems comparable to those of conventional loading. Keywords: Implant overdenture, Immediate loading, Marginal bone level changes, Radiographic assessment
机译:摘要:目的:比较支持下颌植入物覆盖(IOD)的立即和常规装载的植入物的边缘骨水平变化(MBLC)。材料和方法:为电子(Medline,PubMed和Cochrane图书馆)和手工搜索都是针对2017年1月1日至11月1日发布的所有相关研究进行的。随机对照试验(RCT)和预期研究最低 - 选择了12个月。利用植入物较窄3mm的研究被排除在分析之外。结果:四项研究达到标准,两项评价水平骨质损失。试验组中有70名患者(立即加载)和60例,在对照组中(常规装载)。随访持续了6-36个月,MBLC被解释为标准化的悬垂X射线,全景或锥梁计算断层扫描。每位患者被给予2-3种植体。在6和12个月内,MBLC的差异分别为0.04mm(95%CI:-0.21,0.29)和0.00mm(95%CI:-0.35,0.36)。具有2种植入物的RCT亚组分析显示MBLCS的组差异为0.13mm(95%CI:-0.22,0.48),水平骨损失为0.04 mm(95%CI:-0.02,0.10)。没有鉴定统计学上显着的差异(p> 0.05)。结论:颌骨IOD立即加载的植入物的MBLC似乎与常规负载相当。关键词:植入物覆盖,立即加载,边际骨水平变化,放射线评估

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号