首页> 外文OA文献 >Efficacy of Two Cleaning Solutions for the Decontamination of 10 Antineoplastic Agents in the Biosafety Cabinets of a Hospital Pharmacy
【2h】

Efficacy of Two Cleaning Solutions for the Decontamination of 10 Antineoplastic Agents in the Biosafety Cabinets of a Hospital Pharmacy

机译:两种清洁溶液在医院药房生物安全柜中10例抗肿瘤剂去污的疗效

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: This study aimed to evaluate two cleaning solutions for the chemical decontamination of antineoplastic agents on the surfaces of two biosafety cabinets routinely used for chemotherapy preparation in a hospital pharmacy. Methods: For almost 1 year (49 weeks), two different solutions were used for the weekly cleaning of two biosafety cabinets in a hospital pharmacy's centralized cytotoxic preparation unit. The solutions evaluated were a commercial solution of isopropyl alcohol (IPA) and water (70:30, vol:vol), and a detergent solution constituted by 10-2M of sodium dodecyl sulfate (SDS) with 20% IPA. Seven areas in each biosafety cabinet were wiped 14 times throughout the year, before and after the weekly cleaning process, according to a validated procedure. Samples were analyzed using a validated method of high-performance liquid chromatography coupled to mass spectrometry. The decontamination efficacy of these two solutions was tested for 10 antineoplastic agents: cytarabine, gemcitabine, methotrexate, etoposide phosphate, irinotecan, cyclophosphamide, ifosfamide, doxorubicin, epirubicin, and vincristine. Results: Overall decontamination efficacies observed were 82±6% and 49±11% for SDS solution and IPA, respectively. Higher contamination levels were distributed on areas frequently touched by the pharmacy technicians—such as sleeves and airlock handles—than on scale plates, gravimetric control hardware, and work benches. Detected contaminations of cyclophosphamide, ifosfamide, gemcitabine, and cytarabine were higher than those of the others agents. SDS solution was almost 20% more efficient than IPA on eight of the antineoplastic agents. Conclusion: Both cleaning solutions were able to reduce contamination levels in the biosafety cabinets. The efficacy of the solution containing an anionic detergent agent (SDS) was shown to be generally higher than that of IPA and, after the SDS cleaning procedure, biosafety cabinets demonstrated acceptable contamination levels
机译:目的:本研究旨在评估抗肿瘤药通常用于在医院药房化疗两种制备生物安全柜的表面化学除污两个清洁解决方案。方法:将近1年(49周),分别用于两个生物安全柜在医院药房的集中细胞生成装置的每周清洁两种不同的解决方案。评价的溶液是异丙醇(IPA)和水(70:30,体积:体积)的市售溶液,并通过十二烷基硫酸钠10-2M(SDS),用20%IPA组成的洗涤剂溶液。每个生物安全柜七个方面是根据经过验证的过程,全年擦14次,前后每周清洗过程之后。使用耦合到质谱高效液相色谱法的一个有效的方法分析样品。阿糖胞苷,吉西他滨,甲氨蝶呤,磷酸依托泊苷,依立替康,环磷酰胺,异环磷酰胺,多柔比星,表柔比星和长春新碱:这两种溶液的净化功效为10的抗肿瘤剂进行测试。结果:观察到的总体去污效力分别为82±6%,对于分别SDS溶液和IPA,49±11%。高污染水平分布在经常由药学技术人员,如袖子,把手气闸,比刻度板,重量控制硬件和工作台接触的地方。环磷酰胺,异环磷酰胺,吉西他滨和阿糖胞苷的检测污染较其他药物高。 SDS的解决方案几乎是20%,比IPA更有效的抗肿瘤药八。结论:清洁解决方案能够减少在生物安全柜的污染水平。含有阴离子洗涤剂剂(SDS)溶液的效力被证明是一般比IPA的高,并且在SDS清洗过程之后,生物安全柜表明可接受的污染水平

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号