This work studies the lap-shear strength performance of polyethylene pipeline bonded with acrylic adhesive in the temperature range -10 to +20 °C. Single lap shear test samples were firstly prepared at 20 °C under various clamping pressures and curing times to determine suitable conditions under which to prepare and test further samples at temperatures of -10, -5, 0, +5 and +20 °C. It was found that a decrease in curing/testing temperature to zero degrees resulted in a steady reduction in the lap-shear strength performance of the bonded joints from a mean value of 2.72 MPa at +20 °C to 1.15 MPa at 0 °C. Below zero degrees the strength of the bonded substrates was significantly reduced; no samples bonded at -5 °C had sufficient strength to test and only one sample bonded -10 °C was tested, which had very low strength of 0.105 MPa.
机译:这项工作研究了在-10至+20°C的温度范围内用丙烯酸粘合剂粘结的聚乙烯管道的搭接剪切强度性能。首先在20℃下在各种夹紧压力和固化时间下制备单搭接剪切测试样品,以确定合适的条件,在该条件下制备并在-10,-5、0,+ 5和+ 20℃的温度下测试其他样品。发现将固化/测试温度降低至零度会导致粘结接头的搭接剪切强度性能从+20°C的平均值2.72 MPa稳定降低到0°C的1.15 MPa。低于零度,粘合基材的强度显着降低。没有样品在-5°C下粘合时具有足够的强度进行测试,只有一个样品在-10°C下粘合时具有0.105 MPa的极低强度。