首页> 外文OA文献 >Evaluation of percutaneous unilateral trans-femoral implantation of side-hole port-catheter system with coil only fixed-catheter-tip for hepatic arterial infusion chemotherapy
【2h】

Evaluation of percutaneous unilateral trans-femoral implantation of side-hole port-catheter system with coil only fixed-catheter-tip for hepatic arterial infusion chemotherapy

机译:用于肝动脉输液化疗的线圈外孔 - 导管系统经皮单侧慢性股骨头植入的评价

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background The technique for arterial infusion chemotherapy (HAIC) is not standardized which limits its widely application. The aim of this study was to evaluate the long-term functionality and complications of port-catheter system using percutaneous unilateral trans-femoral implantation with coil only fixed-catheter-tip method. Methods From January 2013 to January 2017, 205 consecutive patients (138 men; aged 28–88 years; mean, 59.1 ± 11.2 years) with unresectable malignant liver tumors underwent percutaneous implantation of side-hole infusion port-catheter into hepatic artery using coil only fixed-catheter-tip method via the unilateral femoral artery. Technical success, procedure time, duration of port functionality, and complications of port dysfunction were investigated. Results Implantation technical success was 98.5% and the procedure time was 59.1 ± 10.2 min. Predictable functionality of the port-catheter system at 6-, 12-, and 24 months were 97.5, 89.9, 70.5%, respectively. Complications of port irreversible dysfunction were hepatic artery obstruction (4.0%), catheter occlusion (3.5%), and catheter dislocation (0.5%). Median 5 HAIC cycles (range: 1–14 cycles) were received via port. Conclusion Percutaneous unilateral trans-femoral implantation of a side-hole port-catheter with coils only fixed-catheter-tip method is a simple and feasible interventional technique for HAIC which offers long-term functionality.
机译:抽象背景用于动脉灌注化疗(HAIC)的技术不是标准化限制了其广泛的应用。本研究的目的是评估长期功能和使用经皮单方面反式股骨植入线圈仅固定导管尖端方法端口导管系统的并发症。方法自2013年1月至2017年1月,连续205名患者(男性138;年龄28-88岁,平均59.1±11.2岁),不可切除的恶性肝肿瘤接受侧孔输注端口导管的经皮植入到肝动脉仅使用线圈通过单侧股动脉固定导管尖端方法。技术成功,手术时间,港口功能的持续时间,以及港口功能障碍并发症进行了调查。结果植入技术成功率为98.5%,并且该过程时间为59.1±10.2分钟。在6点,12和24个月的端口导管系统的可预测功能分别为97.5,89.9,70.5%,分别。的端口不可逆功能障碍的并发症是肝动脉梗阻(4.0%),导管阻塞(3.5%),和导管错位(0.5%)。中值5个HAIC周期(范围:1-14个循环)经由端口收到的。的侧孔导管药盒具有线圈的结论经皮单方面反式股骨植入只有固定导管尖端方法是用于HAIC其提供长期功能的简单可行的介入技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号