首页> 外文OA文献 >Polyvinyl Chloride Modified Carbon Paste Electrodes for Sensitive Determination of Levofloxacin Drug in Serum, Urine, and Pharmaceutical Formulations
【2h】

Polyvinyl Chloride Modified Carbon Paste Electrodes for Sensitive Determination of Levofloxacin Drug in Serum, Urine, and Pharmaceutical Formulations

机译:聚氯乙烯改性碳糊电极,用于血清,尿液和药物制剂中左氧氟沙星药物的敏感测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Levofloxacin (LF) is a medically important antibiotic drug that is used to treat a variety of bacterial infections. In this study, three highly sensitive and selective carbon paste electrodes (CPEs) were fabricated for potentiometric determination of the LF drug: (i) CPEs filled with carbon paste (referred to as CPE); (ii) CPE coated (drop-casted) with ion-selective PVC membrane (referred to as C-CPE); (iii) CPE filled with carbon paste modified with a plasticizer (PVC/cyclohexanone) (referenced as P-CPE). The CPE was formulated from graphite (Gr, 44.0%) and reduced graphene oxide (rGO, 3.0%) as the carbon source, tricresyl phosphate (TCP, 47.0%) as the plasticizer; sodium tetrakis[3,5-bis(trifluoromethyl)phenyl] borate (St-TFPMB, 1.0%) as the ion exchanger; and levofloxacinium-tetraphenylborate (LF-TPB, 5.0%) as the lipophilic ion pair. It showed a sub-Nernstian slope of 49.3 mV decade−1 within the LF concentration range 1.0 × 10−2 M to 1.0 × 10−5 M, with a detection limit of 1.0 × 10−5 M. The PVC coated electrode (C-CPE) showed improved sensitivity (in terms of slope, equal to 50.2 mV decade−1) compared to CPEs. After the incorporation of PVC paste on the modified CPE (P-CPE), the sensitivity increased at 53.5 mV decade−1, indicating such improvement. The selectivity coefficient (log KLF2+,Fe+3pot.) against different interfering species (Na+, K+, NH4+, Ca2+, Al3+, Fe3+, Glycine, Glucose, Maltose, Lactose) were significantly improved by one to three orders of magnitudes in the case of C-CPE and P-CPE, compared to CPEs. The modification with the PVC membrane coating significantly improved the response time and solubility of the LF-TPB within the electrode matrix and increased the lifetime. The constructed sensors were successfully applied for LF determination in pharmaceutical preparation (Levoxin® 500 mg), spiked urine, and serum samples with high accuracy and precision.
机译:左氧氟沙星(LF)是一种用于治疗各种细菌感染的医学上重要的抗生素药物。在这项研究中,三个高度灵敏的和选择性的碳糊电极(CPE的),用于电位测定的LF药物的制备了:(ⅰ)的CPE填充有碳糊(称为CPE); (ⅱ)CPE涂覆(滴铸)用离子选择性PVC膜(被称为C-CPE); (ⅲ)CPE填充有碳糊与增塑剂(PVC /环己酮)(如P-CPE引用)改性。所述CPE从石墨(GR,44.0%)和还原的石墨烯氧化物(RG0,3.0%)作为碳源,磷酸三甲苯酯(TCP,47.0%),为增塑剂配制;钠,四[3,5-双(三氟甲基)苯基]硼酸盐(ST-TFPMB,1.0%)作为离子交换剂;和levofloxacinium四苯基硼酸酯(LF-TPB,5.0%),为亲脂性离子对。它表现出49.3毫伏十年-1 LF浓度范围内为1.0×10-2 M至1.0×10 -5 M的子能斯特斜率,以1.0×10-5 M的PVC涂覆的电极的(C检测限-CPE)显示出改善的灵敏度(在斜率方面,等于相比的CPE 50.2毫伏十年-1)。 PVC的掺入所修改的CPE(P-CPE)粘贴后,将灵敏度提高在53.5毫伏十年-1,这表明这样的改进。的选择性系数(log KLF2 +,铁+ 3pot。)针对不同的干扰物种(钠+,K +,NH4 +和Ca2 +,Al 3+的,Fe3 +的,甘氨酸,葡萄糖,麦芽糖,乳糖)由在壳体一至三个数量级的均显著改善C-CPE和P-CPE,对比的CPE。与PVC膜显著涂覆修改改善了电极矩阵内的响应时间和LF-TPB的溶解度并增加了寿命。将构建的传感器被成功地应用于LF测定药物制剂(Levoxin®500毫克),加标尿,和血清样品以高准确度和精确度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号