摘要

PURPOSE:The aim was to assess personalised contrast media (CM) protocols-based on patient's blood volume (BV) and automated tube voltage selection (ATVS)-in coronary computed tomography angiography (CCTA). METHODS:A total of 114 consecutive patients received an ECG-triggered or ECG-gated helical scan on a 3rd-generation dual-source CT with 70-120kV (ATVS) and 330mAsqual.ref. CM was adapted to BV, scan time (s) and kV. Image quality (IQ) was assessed in a 17-segment coronary model using attenuation values (HU), contrast-to-noise (CNR), signal-to-noise ratio (SNR) (objective IQ) and a Likert scale (subjective IQ: 1 = poor/2 = sufficient/3 = good/4 = excellent). ig. RESULTS:Patient distribution was: n = 60 for 70kV, n = 37 80kV and n = 17 90kV. Mean BV was 5.4±0.6L for men and 4.1±0.6L for women. Mean CM volume (300 mg I/mL) and flow rate were: 30.9±6.4mL and 3.3±0.5mL/s (70kV); 40.8±7.1mL and 4.5±0.6mL/s (80kV); 53.6±8.6mL and 5.7±0.6mL/s (90kV). Overall mean HU was >300HU in 98.2% (112/114) of patients. Overall mean attenuation was below 300HU in two scans (70kV) due to late scan timing. Of 1.661 segments, 95.4% was assessable. Mean CNR was 14±4(70kV), 13±3(80kV) and 14±4(90kV); mean SNR was 10±2(both 70kV+80kV) and 9±2(90kV). Objective IQ was comparable between kV settings, protocols and sex. Subjective IQ was diagnostic in all scans and excellent-sufficient in 95.4% of segments. CONCLUSIONS:Personalisation of CCTA CM injection protocols to BV and ATVS is a promising technique to tailor CM administration to the individual patient, while maintaining diagnostic IQ.
机译:目的:目的是评估个性化的造影剂(CM)协议 - 基于患者的血容量(BV)和自动管电压选择(ATV) - 冠状动脉的计算机断层造影血管造影(CCTA)。方法:共有114名连续患者在第三代双源CT上接收ECG触发或ECG门控扫描,具有70-120kV(ATV)和330masqual.ref。 CM适用于BV,扫描时间和kV。使用衰减值(HU),对比度 - 噪声(CNR),信噪比(SNR)(客观IQ)和李克特量表(主体IQ)在17段冠状动脉模型中评估图像质量(IQ)。 :1 =差/ 2 =足够/ 3 =好/ 4 =优秀)。 IG。结果:患者分布是:n = 60持续70kV,n = 37 80kV和n = 17 90kV。平均BV为男性为5.4±0.6L,女性为4.1±0.6L。平均cm体积(300mg I / ml)和流速为:30.9±6.4ml和3.3±0.5ml / s(70kV); 40.8±7.1ml和4.5±0.6ml / s(80kV); 53.6±8.6ml和5.7±0.6ml / s(90kV)。总体意味着胡锦涛在98.2%(112/114)的患者中是300hu。由于后期扫描时序,总体平均衰减在两次扫描(70kV)中低于300湖。 1.661段,95.4%是可评估的。平均CNR为14±4(70kV),13±3(80kV)和14±4(90kV);平均SNR为10±2(70kV + 80kV)和9±2(90kV)。目标IQ与KV设置,协议和性别之间相当。主观智商在所有扫描中诊断,均为95.4%的群体。结论:CCTA CM注射方案到BV和ATV的个性化是一种希望达到个体患者的癌症,同时保持诊断智商。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号