摘要

Background and purpose — Uncemented cups in total hip arthroplasty (THA) are often augmented with additional screws to enhance their primary stability. We investigated whether there is a difference in the risk for revision between cups with screw holes and cups without screw holes. Patients and methods — We analyzed the risk for cup revision of uncemented cups registered in the Swedish Hip Arthroplasty Register (SHAR) between 2000 and 2017 with respe ct to the presence of screw holes. Only patients with primary osteoarthritis (OA) were included. 22,725 cups, including 12,354 without screw holes and 10,371 with screw holes, were evaluated. Revision rates at 2 and 10 years after the primary operation were analyzed. Results — At a median follow-up time of 3.4 years (0–18), 459 cup revisions were reported. The main reasons for cup revision during the whole observation time were infection, 52% of all cup revisions, and dislocation, 26% of all cup revisions. The survival rate with cup revision due to aseptic loosening as endpoint was 99.9% (95% CI 99.8–99.9) at 2 years for both cups with and cups without screw holes, and the survival rates at 10 years were 99.5% (CI 99.3–99.7) and 99.1% (CI 98.6–99.5), respectively. Cups without screw holes showed a decreased risk of revision due to any reason at both 2 years (adjusted hazard ratio [HR] 0.6, CI 0.5–0.8) and 10 years (HR 0.7, CI 0.5–0.9). Interpretation — We found a very low revision rate for aseptic loosening with modern, uncemented cup designs. Cups with screw holes had an increased risk of revision due to any reason in patients with primary OA
机译:背景和目的 - 在全髋关节置换(THA)非骨水泥杯通常与附加螺钉增强以提高其初期稳定性。我们调查是否有没有螺丝孔的螺纹孔杯和杯之间的修订风险的差异。患者和方法 - 我们分析与respe克拉2000年至2017年间在瑞典髋关节置换寄存器(SHAR)注册的螺丝孔存在非骨水泥杯的杯修订的风险。只有具有原发性骨关节炎(OA)患者。 22725杯,包括12354无螺纹孔和10371有螺纹孔,进行了评价。在一次手术后2年和10年翻修率进行了分析。结果 - 在3.4岁(0-18)中位随访时间,据报459次修订。在整个观测时间杯修订的主要原因是感染,所有的杯子修订的52%,脱位,所有杯修订的26%。的生存率杯修订由于无菌性松动为端点2年为99.9%(95%CI 99.8-99.9),用于与两个杯和杯无螺纹孔,并且在10年存活率分别为99.5%(CI 99.3- 99.7)和99.1%(CI 98.6-99.5),分别。无螺纹孔杯表明由于任何原因在两个2年(调整后的危险比(HR)0.6,CI 0.5-0.8)和10岁(HR 0.7,CI 0.5-0.9)降低的版本的危险。解读 - 我们发现与现代,非骨水泥杯设计松动非常低的翻修率。螺孔杯有修订的风险增加,由于任何原因原发性OA

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号