首页> 外文OA文献 >In vivo kinematics of knee replacement during daily living activities: Condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses
【2h】

In vivo kinematics of knee replacement during daily living activities: Condylar and post-cam contact assessment by three-dimensional fluoroscopy and finite element analyses

机译:在日常生活活动期间膝关节替代的体内运动学:髁突和凸轮后的三维荧光检查和有限元分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In total knee replacement, the investigation on the exact contact patterns at the post-cam in implanted patients from real in vivo data during daily living activities is fundamental for validating implant design concepts and assessing relevant performances. This study is aimed at verifying the restoration of natural tibio-femoral condylar kinematics by investigating the post-cam engagement at different motor tasks. An innovative validated technique, combining three-dimensional fluoroscopic and finite element analyses, was applied to measure joint kinematics during daily living activities in 15 patients implanted with guided motion posterior-stabilized total knee replacement. Motion results showed physiological antero-posterior translations of the tibio-femoral condyles for every motor task. However, high variability was observed in the position of the calculated pivot point among different patients and different motor tasks, as well as in the range of post-cam engagement. Physiological tibio-femoral joint rotations and contacts at the condyles were found restored in the present knee replacement. Articular contact patterns experienced at the post-cam were found compatible with this original prosthesis design. The present study reports replaced knee kinematics also in terms of articular surface contacts, both at the condyles and, for the first time, at the post-cam. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1396–1403, 2017.
机译:总膝盖替换,对日常生活活动中植入患者的植入患者的植入患者的确切接触模式的调查是验证植入设计理念和评估相关表演的基础。本研究旨在通过调查不同电动机任务的凸轮啮合来验证自然胫骨髁突动力学的恢复。一种创新的经过验证的技术,组合三维荧光透视和有限元分析,应用于在15名患者中植入的每日活性活动期间测量关节运动学,植入引导议案后稳定的全膝关节置换。运动结果表明,各个电机任务的胫骨髁突的生理前后翻译。然而,在不同患者和不同的电动机任务中的计算枢轴点的位置观察到高变异性,以及在凸轮后接合的范围内。发现在本膝关节置换中恢复了髁上的生理学胫骨关节旋转和触点。发现在凸轮后的关节接触模式与该原始的假体设计兼容。本研究报告还以髁上的关节表面触点而替换膝关节运动学,并且首次在后凸轮上。 ©2016骨科研究会。由Wiley期刊出版,Inc.J Orthop Res 35:1396-1403,2017。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号