首页> 外文OA文献 >Effect of three different needle holders on gastrointestinal anastomosis construction time and bursting pressure in equine jejunal segments
【2h】

Effect of three different needle holders on gastrointestinal anastomosis construction time and bursting pressure in equine jejunal segments

机译:三种不同针座对胃肠吻合型建筑时间和爆破压力的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine. The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time. Single layer end-to-end jejunojejunal anastomoses were performed on jejunal segments harvested from equine cadavers. These segments were randomly allocated to four groups. Three groups based on the needle holder type that was used: 16.5 cm Frimand (Group 1), 16 cm Mayo-Hegar (Group 2) or 20.5 cm Mayo-Hegar (Group 3) needle holders. One (Group 4) as control without anastomoses. Anastomosis construction time was recorded. Bursting pressure was determined by pumping green coloured fluid progressively into the lumen whilst recording intraluminal pressures. Maximum pressure reached prior to failure was recorded as bursting pressure. Construction times and bursting pressures were compared between needle holder, and the correlation between bursting pressure and construction time was estimated. Results Construction times were not statistically different between groups (P = 0.784). Segments from Group 2 and Group 3 burst at a statistically significantly lower pressure than those from Group 4; P = 0.031 and P = 0.001 respectively. Group 4 and Group 1 were not different (P = 0.125). The mean bursting pressure was highest in Group 4 (189 ± 61.9 mmHg), followed by Group 1 (166 ± 31 mmHg) and Group 2 (156 ± 42 mmHg), with Group 3 (139 ± 34 mmHg) having the lowest mean bursting pressure. Anastomosis construction time and bursting pressure were not correlated (P = 0.792). Conclusions The tested needle holders had a significant effect on bursting pressure, but not on anastomosis construction time. In an experimental setting, the Frimand needle holder produced anastomoses with higher bursting pressures. Further studies are required to determine clinical implications.
机译:摘要背景马上小肠切除和吻合术是一种过程优化速度,而不会受到完整性,是有利的。有一系列不同的针座可用,但在兽医中的外科手术仪器上发表了很少的公布。本研究的目标是调查针座类型是否会影响吻合型结构时间,吻合突起压力以及爆破压力是否受到吻合结构的影响。单层端到端Jejunojejunal吻合吻合吻合在马尸尸体中收获的Jejunal段中进行。将这些段随机分配给四组。三组基于使用的针夹型,使用:16.5cmmand(组1),16cm mayo-hegar(第2组)或20.5cm mayo-hegar(3)针座。一个(第4组)作为没有吻合的控制。记录吻合结构时间。通过在记录腔内压力的同时通过逐渐泵入腔内来确定突发压力。故障之前达到的最大压力被记录为爆破压力。在针架之间比较施工时间和爆破压力,估计爆破压力和施工时间之间的相关性。结果施工时间在组之间没有统计学不同(P = 0.784)。第2组和第3组的段在统计上显着较低的压力比4组; p = 0.031和p = 0.001分别。第4组和第1组并不不同(P = 0.125)。第4组(189±61.9mmHg)的平均爆破压力最高,其次是第1组(166±31mmHg)和第2组(156±42 mmHg),第3组(139±34 mmHg),具有最低的平均爆破压力。吻合型结构时间和爆破压力不相关(p = 0.792)。结论测试的针刺器对爆破压力有显着影响,但不是吻合施工时间。在实验设置中,浑浊针刺器产生具有更高爆破压力的吻合。进一步的研究需要确定临床意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号