首页> 外文OA文献 >Shear Wave Elastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects
【2h】

Shear Wave Elastography of the Plantar Fascia: Comparison between Patients with Plantar Fasciitis and Healthy Control Subjects

机译:Purtorar筋膜的剪力波弹性显影:跖跖和健康对照患者之间的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The purpose of this study was to evaluate plantar fasciae of healthy subjects and patients with plantar fasciitis by shear wave velocity (SWV) and stiffness with correlation to B-Mode and color Doppler ultrasonography (CDUS) and to establish cut-off values. Methods: This observational study was conducted with the approval of the Institutional Review Boards (IRBs) of our institution. 108 unilateral plantar fasciae were evaluated by including 87 consecutive patients (mean age 51.7; range: 29–82) (66 women and 21 men) with plantar fasciitis and 21 asymptomatic age matched healthy volunteers (mean age 47.3; range: 32–58) (15 women and 6 men). All patients were prospectively imaged between July 2018 and March 2019. B-mode US was used to measure thickness and CDUS to grade vascularity. SWE measurements were repeated 3 times and mean was used for statistical analysis. Results: Mean SWV value in healthy subjects was 6.94 m/s and in patients 4.98 m/s with a mean stiffness value of 152.88 kPa and 93.54 kPa respectively (p < 0.001). For SWV a cut-off value of 6.16 m/s had a specificity of 80.95% and sensitivity of 79.31%. For stiffness a cut-off value of 125.57 kPa had a specificity of 80.95% and sensitivity of 80.46%. No correlation to CDUS was found. The mean thickness of healthy fascias was 3.3 mm (range 2.4–3.9) compared to 6.1 mm (range 2.0–22.0) in plantar fasciitis (p < 0.001) with no correlation to SWV or to stiffness (r² = 0.02, p = 0.06). Conclusion: SWE allows quantitative assessment of plantar fascia stiffness, which decreases in patients with plantar fasciitis. No correlation to the thickness of the plantar fascia was found, therefore it represents an independent factor for the diagnosis of plantar fasciitis and could be helpful in addition to thickness measurement in unclear cases.
机译:背景:本研究的目的是通过剪切波速(SWV)和刚度与B模式和彩色多普勒超声(CDU)相关并建立截止值,评估健康受试者和跖骨炎患者的Portorar筋膜患者。方法:该观察研究是通过我们机构的机构审查委员会(IRB)的批准进行的。 108个单侧跖跖通过包括87名连续患者(平均51.7岁;范围:29-82)(66名女性和21名男性),具有跖筋炎和21例无症状时代匹配的健康志愿者(平均47.3;范围:32-58) (15名妇女和6名男子)。所有患者均在2018年7月至2019年3月之间进行了前瞻性成像。B模式美国用于测量厚度和CDU以级别血管。重复SWE测量3次,平均用于统计分析。结果:健康受试者的平均值为6.94米/秒,患者4.98米/秒,平均刚度值分别为152.88kPa和93.54kPa(p <0.001)。对于SWV,截止值为6.16m / s的特异性为80.95%,灵敏度为79.31%。对于刚度的截止值125.57kPa的特异性为80.95%,敏感性为80.46%。没有发现与CDU的相关性。健康罩的平均厚度为3.3mm(范围2.4-3.9),相比于跖骨筋膜炎(P <0.001),与SWV或刚度无关(R 2 = 0.02,P = 0.06) 。结论:SWE允许对跖筋僵硬度进行定量评估,血小板筋膜炎患者减少。没有发现与Purtorar筋膜的厚度相关,因此它代表了诊断跖筋炎的独立因素,并且除了粗糙的情况下除了厚度测量外,还具有有帮助的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号