首页> 外文OA文献 >Postoperative mechanical alignment analysis of total knee replacement patients operated with 3D printed patient specific instruments: A Prospective Cohort Study
【2h】

Postoperative mechanical alignment analysis of total knee replacement patients operated with 3D printed patient specific instruments: A Prospective Cohort Study

机译:术后膝关节置换患者的术后机械对准分析,3D印刷患者特定仪器:一项潜在队列研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Objective: Total knee replacement (TKR) is a surgical treatment for final stage gonarthrosis. The lifespan of the prosthetic implants used in TKR surgery is a major interest for the orthopaedic research community.Previously, proper implant alignment of the implants has been advocated for longevity of the TKR surgery. Recently, patient-specific (PSI) instruments have been proposed to improve the mechanical alignment of the TKR by permitting better implant positioning over conventional TKR surgery. The aim of this study is to compare the mechanical alignment results of patients operated with PSIs and conventional instruments. Methods: Two groups of 20 patients chosen in a quasi-random manner have been compared in this study. In the first group femoral distal and tibial osteotomies were made by a PSI which was produced by the patients' computed tomography scans. All osteotomies in the control group were made with the TKR set's routine instruments by conventional means. Patients' preoperative and postoperative mechanical femorotibal angles (mFTA), femoral coronal angles (FCA), tibial coronal angles (TCA) were measured and the number of outliers which showed more than 3° of malalignment were counted in both groups for comparison. Results: The average postoperative mFTA was found to be 2.09° for the PSI group and in was found to be 2.84° for the control which was not statistically significant. The comparison of postoperative FCA and TCA also did not show significant difference between the groups. The number of outliers showing more than 3° of malalignment per group were found to be 1 out of 20 (5%) for the PSI group and 7 out of 20 (35%) for the control which was statistically significant. Conclusion: In this study patient-specific instrumentation provided significantly better mechanical alignment compared to conventional TKR for the frequency of outlier cases with malalignment beyond 3°. PSI proved no significant difference when the groups were compared for mFTA, FCA and TCA. Our findings support that PSI may improve TKR alignment by improving the ratio of the outlier patients with marked malalignment. Level of Evidence: Level III, Therapeutic Study. Keywords: Total knee replacement, Total knee arthroplasty, Mechanical alignment, Patient specific instruments, Patient matched instruments
机译:目的:全膝关节置换术(TKR)是一种外科治疗最后阶段膝关节病。在TKR手术中使用的假体植入物的使用寿命是骨科研究community.Previously,植入物的适当的植入物对准已经主张对TKR手术长寿的一大兴趣。近日,针对特定患者的(PSI)的仪器已经提出通过允许比传统手术TKR更好植入物定位,以提高TKR的机械调整。本研究的目的是比较用的PSI和常规仪器操作患者机械对准结果。方法:两组在一个类似随机的方式选择了20名患者在这项研究进行了比较。在第一组中的股骨远端和胫骨切骨术通过将其通过患者的CT扫描生成的PSI被做了。对照组中的所有截骨用常规手段TKR组的日常文书。患者的术前和术后机械femorotibal角(mFTA),股骨冠状角(FCA),胫骨冠角(TCA)进行测定,其显示异常值的数目多于排列不齐的3°两组计数进行比较。结果:平均术后mFTA被发现是°为PSI组和被发现是2.84°,其为无统计学显著控制2.09。术后FCA和TCA的比较也没有表现出组间差异显著。离群值表示每组排列不齐的大于3°的数量被认为是1的20个(5%)为PSI组和7出20(35%)为有统计学显著控制的。结论:在本研究中患者特异性器械相比,离群例排列不齐的频率超过3°常规TKR提供显著更好的机械对准。当组分别为mFTA,FCA和TCA相比PSI证明没有显著差异。我们的发现支持了PSI可以通过改进的异常值的患者标记的排列不齐的比率提高TKR对准。证据级别:三级,治疗研究。关键词:全膝关节置换术,全膝关节置换术,机械定位,病人专用仪器,患者匹配器械

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号