首页> 外文OA文献 >On-Line Partial Discharge Monitoring System for Power Transformers Based on the Simultaneous Detection of High Frequency, Ultra-High Frequency, and Acoustic Emission Signals
【2h】

On-Line Partial Discharge Monitoring System for Power Transformers Based on the Simultaneous Detection of High Frequency, Ultra-High Frequency, and Acoustic Emission Signals

机译:基于同时检测高频,超高频和声发射信号的电力变压器在线局部放电监控系统

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The article presents a novel on-line partial discharge (PD) monitoring system for power transformers, whose functioning is based on the simultaneous use of three unconventional methods of PD detection: high-frequency (HF), ultra-high frequency (UHF), and acoustic emission (AE). It is the first monitoring system equipped in an active dielectric window (ADW), which is a combined ultrasonic and electromagnetic PD sensor. The article discusses in detail the process of designing and building individual modules of hardware and software layers of the system, wherein the most attention was paid to the PD sensors, i.e., meandered planar inverted-F antenna (MPIFA), high-frequency current transformer (HFCT), and active dielectric window with ultrasonic transducer, which were optimized for detection of PDs occurring in oil-paper insulation. The prototype of the hybrid monitoring system was first checked on a 330 MVA large power transformer during the induced voltage test with partial discharge measurement (IVPD). Next, it was installed on a 31.5 MVA substation power transformer and integrated according to the standard IEC 61850 with SCADA (Supervisory Control and Data Acquisition) system registering voltage, active power, and oil temperature of the monitored unit. The obtained results showed high sensitivity of the manufactured PD sensors as well as the advantages of the simultaneous use of three techniques of PD detection and the possibility of discharge parameter correlation with other power transformer parameters.
机译:本文介绍了电力变压器的新型局部局部放电(PD)监测系统,其功能基于同时使用三种非传统方法的PD检测方法:高频(HF),超高频(UHF),和声学发射(AE)。它是配备在有源电介质窗口(ADW)中的第一监控系统,其是组合的超声波和电磁PD传感器。本文详细讨论了设计和构建系统的硬件和软件层的单个模块的过程,其中最受关注的是PD传感器,即蜿蜒的平面倒-F天线(MPIFA),高频电流互感器(HFCT)和具有超声换能器的有源介电窗,该介电窗口被优化以检测在油纸绝缘中发生的PD。在具有局部放电测量(IVPD)的感应电压测试期间,首先在330MVA大型电力变压器上检查混合监测系统的原型。接下来,它安装在31.5 MVA变电站电力变压器上,并根据标准IEC 61850进行集成,具有SCADA(监控和数据采集)系统注册电压,有功功率和监控单元的油温。所得结果显示出制造的PD传感器的高灵敏度,以及同时使用PD检测技术的三种技术以及与其他电力变压器参数的放电参数相关性的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号