首页> 外文OA文献 >Validation of triaxial accelerometers to measure the lying behaviour of adult domestic horses
【2h】

Validation of triaxial accelerometers to measure the lying behaviour of adult domestic horses

机译:验证三轴加速度计测量成人家畜的撒谎行为

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Examining the characteristics of an animal’s lying behaviour, such as frequency and duration of lying bouts, has become increasingly relevant for animal welfare research. Triaxial accelerometers have the advantage of being able to continuously monitor an animal’s standing and lying behaviour without relying on live observations or video recordings. Multiple models of accelerometers have been validated for use in monitoring dairy cattle; however, no units have been validated for use in equines. This study tested Onset Pendant G data loggers attached to the hind limb of each of two mature Standardbred horses for a period of 5 days. Data loggers were set to record their position every 20 s. Horses were monitored via live observations during the day and by video recordings during the night to compare activity against accelerometer data. All lying events occurred overnight (three to five lying bouts per horse per night). Data collected from the loggers was converted and edited using a macro program to calculate the number of bouts and the length of time each animal spent lying down by hour and by day. A paired t-test showed no significant difference between the video observations and the output from the data loggers (P=0.301). The data loggers did not distinguish standing hipshot from standing square. Predictability, sensitivity, and specificity were all >99%. This study has validated the use of Onset Pendant G data loggers to determine the frequency and duration of standing and lying bouts in adult horses when set to sample and register readings at 20 s intervals.
机译:检查动物撒谎行为的特征,如躺着的频率和持续时间,对动物福利研究变得越来越相关。三轴加速度计具有能够连续监测动物的站立和撒谎行为而不依赖于实时观测或视频录制。多种型号的加速度计已被验证用于监测乳制品牛;但是,没有单位已被验证以用于商标。这项研究测试了在5天的两种成熟标准马匹的每个成熟标准马匹的后肢上附着的发病吊坠G数据记录器。数据记录器设置为每20秒记录其位置。在白天的现场观察和夜间视频录制通过运动观察监测马匹以比较反对加速度计数据的活动。所有谎言活动都发生过夜(每匹马每匹马撒谎三到五个撒谎)。使用宏计划转换和编辑从记录器中收集的数据来计算呼出的数量和每个动物花费躺下时的时间长短。配对T检验显示视频观察和数据记录器的输出之间没有显着差异(P = 0.301)。数据记录器没有区分站立距离常设正方形。可预测性,敏感性和特异性均为99%。本研究已验证使用发起吊坠G数据记录器,以确定在成人马中的频率和持续时间,当设置为以20秒的间隔设定和注册读数时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号