首页> 外文OA文献 >Comparative Thermodynamic Analysis of Kalina and Kalina Flash Cycles for Utilizing Low-Grade Heat Sources
【2h】

Comparative Thermodynamic Analysis of Kalina and Kalina Flash Cycles for Utilizing Low-Grade Heat Sources

机译:Kalina和Kalina Flash循环利用低级热源的比较热力学分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Kalina flash cycle (KFC) is a novel, recently proposed modification of the Kalina cycle (KC) equipped with a flash vessel. This study performs a comparative analysis of the thermodynamic performance of KC and KFC utilizing low-grade heat sources. How separator pressure, flash pressure, and ammonia mass fraction affect the system performance is systematically and parametrically investigated. Dependences of net power and cycle efficiencies on these parameters as well as the mass flow rate, heat transfer rate and power production at the cycle components are analyzed. For a given set of separator pressure and ammonia mass fraction, there exists an optimum flash pressure making exergy efficiency locally maximal. For these pressures, which are higher for higher separator pressure and lower ammonia mass fraction, KFC shows better performance than KC both in net power and cycle efficiencies. At higher ammonia mass fraction, however, the difference is smaller. While the maximum power production increases with separator pressure, the dependence is quite weak for the maximum values of both efficiencies.
机译:Kalina Flash循环(KFC)是一种新颖的,最近提出的kalina循环(KC)配备有闪蒸容器的修改。该研究利用低级热源对KC和KFC的热力学性能进行了比较分析。分离器压力,闪光灯和氨质量分数如何影响系统性能,系统性和参数化研究。分析了净功率和循环效率对这些参数以及循环组分的质量流量,传热率和功率产生的依赖性。对于给定的一组隔膜压力和氨质量分数,存在最佳的闪光压,使得局部最大效率最大。对于较高的分离器压力和低氨质量分数较高的这些压力,KFC在净功率和循环效率下显示比KC更好的性能。然而,在较高的氨质量分数下,差异较小。虽然最大功率产生的功率产生增加,但效率的最大值是相当弱的依赖性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号