首页> 外文OA文献 >Innovative Multi-Site Photoplethysmography Analysis for Quantifying Pulse Amplitude and Timing Variability Characteristics in Peripheral Arterial Disease
【2h】

Innovative Multi-Site Photoplethysmography Analysis for Quantifying Pulse Amplitude and Timing Variability Characteristics in Peripheral Arterial Disease

机译:用于量化脉冲幅度和周围动脉疾病的脉冲幅度和定时变异特性的创新多站点光学仪分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Photoplethysmography (PPG) is a simple-to-perform vascular optics measurement technique that can detect blood volume changes in the microvascular bed of tissue. Beat-to-beat analysis of the PPG waveform enables the study of the variability of pulse features, such as the amplitude and the pulse arrival time (PAT), and when quantified in the time and frequency domains, has considerable potential to shed light on perfusion changes associated with peripheral arterial disease (PAD). In this pilot study, innovative multi-site bilateral finger and toe PPG recordings from 43 healthy control subjects and 31 PAD subjects were compared (recordings each at least five minutes, collected in a warm temperature-controlled room). Beat-to-beat normalized amplitude variability and PAT variability were then quantified in the time-domain using two simple statistical measures and in the frequency-domain bilaterally using magnitude squared coherence (MSC). Significantly reduced normalized amplitude variability (healthy control 0.0384 (interquartile range 0.0217–0.0744) vs. PAD 0.0160 (0.0080–0.0338) (p < 0.0001)) and significantly increased PAT variability (healthy control 0.0063 (0.0052–0.0086) vs. PAD 0.0093 (0.0078–0.0144) (p < 0.0001)) was demonstrated for the toe site in PAD using the time-domain analysis. Frequency-domain analysis demonstrated significantly lower MSC values across a range of frequency bands for PAD patients. These changes suggest a loss of right-to-left body side coherence and cardiovascular control in PAD. This study has also demonstrated the feasibility of using these measurement and analysis methods in studies investigating multi-site PPG variability for a wide range of cardiac and vascular patient groups.
机译:光电容积描记(PPG)是一种简单的对血管进行光学测量技术,可以检测在组织的微血管床血液量的变化。 PPG波形的搏动到节拍分析使脉冲特征,比如幅度和脉冲到达时间(PAT),并且当在时间和频率域定量变异的研究中,有相当大的潜力阐明了外周动脉疾病(PAD)相关联的灌注的变化。在这个试验性研究,创新的多站点双边手指和脚趾PPG从43名健康对照者和31名PAD受试者记录进行比较(每个记录至少五分钟,在温暖的温度受控室收集)。节拍到击败归一化幅度的变化,然后PAT变异性使用两个简单的统计措施的时域量化和频域两侧使用幅度平方相干(MSC)。显著减少归一化幅度的变化(健康对照0.0384(四分位数间距0.0217-0.0744)与PAD 0.0160(0.0080-0.0338)(P <0.0001))和增加显著PAT变异性(健康对照0.0063(0.0052-0.0086)与PAD 0.0093( 0.0078-0.0144)(p 0.0001))证实<用于使用所述时域分析中PAD脚趾部位。频域分析在一系列频带为PAD患者表现出显著较低MSC值。这些变化表明从右到左体侧的连贯性和PAD心血管失控。这项研究还表明使用调查研究,多站点PPG变异性大范围心脏和血管的患者群体的这些测量和分析方法的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号