Administration of low-dose steroids via a catheter inserted into the cochlea to apply pharmaceuticals to more apical regions was previously shown not to be sufficient for long-term reduction of electrode impedances. The aim of the present study was to investigate the effect of intra-cochlear high-dose triamcinolone application on impedances in cochlear implant recipients. Patients received low-dose (4 mg/ml; n = 5) or high-dose (20 mg/ml; n = 5) triamcinolone via a cochlear catheter just prior to the insertion of a Med-El Flex28 electrode. Impedances were measured at defined time points from intra-operatively up to 12 months after first fitting and retrospectively compared with a control group (no steroid application). Patients who received a high-dose application of crystalloid triamcinolone showed significantly reduced impedances in the first fitting measurements compared to the control group. This effect was no longer detectable in patients of the low-dose group at that time. Looking at the different regions of the electrode, the impedance values were lowered significantly only at the basal and medial contacts. At later time points, there were no significant differences between any of the groups. This is the first study to demonstrate a dose-dependent reduction of impedances by deep intra-cochlear injection of triamcinolone in cochlear implant patients. With a high-dose, single application of triamcinolone using a cochlear catheter prior to insertion of a Flex28 electrode, the impedances can be significantly reduced up to and including the first fitting. Although the effect was longer lasting than when compared to low-dose triamcinolone, it was also not permanent.
机译:通过插入耳蜗中的导管施用低剂量类固醇以将药物应用于更多顶端区域,以便足以用于电极阻抗的长期减少。本研究的目的是探讨核心耳内高剂量Triamcinolone应用对耳蜗植入受者的阻抗的影响。在插入Med-EL Flex28电极之前,患者通过耳蜗导管接受低剂量(4mg / ml; n = 5)或高剂量(20mg / ml; n = 5)曲序酮。与对照组(无类固醇应用)相比,在首次拟合后12个月的定义时间点测量阻抗。与对照组相比,接受晶体曲哚酮的高剂量施用的患者在第一拟合测量中显示出显着降低的阻抗。当时低剂量组的患者不再可检测到这种效果。观察电极的不同区域,仅在基底和内侧接触处显着降低阻抗值。在稍后的时间点,任何组之间没有显着差异。这是第一项研究,以证明通过在耳蜗植入患者中深层耳蜗内注射冠状糖酮的细胞内宫内节育脉注射术的剂量依赖性降低。通过高剂量,在插入Flex28电极之前使用耳蜗导管单次施用Triamcinolone,可以显着减少到并包括第一配件的阻抗。虽然效果持久性比低剂量Triamcinolone相比,但它也不是永久性的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号