首页> 外文OA文献 >Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate
【2h】

Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate

机译:前列腺磁共振成像中现代扩散加权成像序列的图像质量和几何变形

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PURPOSE: The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times.udMETHODS AND MATERIALS: Axial T2-weighted turbo spin echo images and axial DWI echo-planar imaging (EPI) sequences, including single-shot spin-echo (ss-EPI), readout-segmented multishot (rs-EPI), selective excitation-reduced field of view (sTX-EPI), and prototype single-shot technique applying slice-specific shimming (iShim-EPI) sequences, were acquired at 3 T in 10 healthy volunteers (mean age, 26.1 ± 3.8 years; body mass index, 23.2 ± 3.0 kg/m). Two radiologists, blinded to the type of DWI, independently rated DWIs on a 5-point Likert scale regarding subjective image quality features (resolution, demarcation of prostate capsule, zonal anatomy). Interreader agreement was assessed using the intraclass correlation coefficient. Signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values were assessed separately in the peripheral and transitional zone. For the analysis of geometric distortion, the diameter of the prostate from left to right and from anterior to posterior was measured at the level of the verumontanum on b-1000 DWIs and on T2-weighted turbo spin echo images. Differences were compared using the Wilcoxon rank sum test for qualitative parameters, analysis of variance, and Friedman test for quantitative parameters. A P value of less than 0.05 was considered significant, with correction for multiple comparisons.udRESULTS: Interreader agreement was good to excellent (intraclass correlation coefficient, 0.71-0.79) for all qualitative features. Subjective image quality regarding "resolution" was significantly better for ss-EPI than rs-EPI (mean Likert score, 4.25 vs 3.8; P = 0.031) and sTX-EPI (4.25 vs 3.3; P = 0.046) and for iShim-EPI as compared with rs-EPI (4.4 vs 3.8; P = 0.031) and sTX-EPI (4.4 vs 3.3; P = 0.047). There was no significant difference regarding capsule demarcation and zonal anatomy. Signal-to-noise ratio was significantly higher in iShim-EPI than sTX-EPI (SNR ± standard deviation [SD], 28.13 ± 8.21 vs 14.96 ± 2.4; P = 0.015). The ADC values were lower for the peripheral zone in the sTX-EPI than in the ss-EPI (ADC ± SD, 1002.94 ± 83.51 vs 1165.05 ± 115.64; P = 0.013) and the rs-EPI (1002.94 ± 83.51 vs 1244.40 ± 89.95; P = 0.0012) and in the transitional zone in the sTX-EPI compared with the rs-EPI (874.50 ± 200.72 vs 1261.47 ± 179.23; P = 0.0021). There were no statistically significant differences in geometric distortion between all DWI sequences.udCONCLUSIONS: Single-shot spin-echo EPI and iShim-EPI showed a tendency toward superior image quality and SNR compared with rs-EPI and sTX-EPI with no significant differences in geometric distortion.
机译:目的:本研究的目的是使用类似的成像参数和类似的采集时间比较前列腺的4个磁共振扩散加权成像(DWI)序列的定性和定量图像质量和几何变形。 Udmethods和材料:轴向T2-加权涡轮增压旋转回波图像和轴向DWI回波平面成像(EPI)序列,包括单次旋转回波(SS-EPI),读出分段多机(RS-EPI),选择性激发缩小视野(STX- EPI)和应用切片特异性匀场(ISHIM-EPI)序列的原型单射技术在10个健康的志愿者中获得(平均年龄,26.1±3.8岁;体重指数,23.2±3.0 kg / m) 。两个放射科医生,蒙蔽了DWI的类型,关于一个关于主观图像质量特征的5点李克特规模的独立评价的DWIS(分辨率,前列腺囊,区间解剖学)。使用腹部相关系数评估中断者协议。在外围和过渡区域中分别评估信噪比(SNR)和表观扩散系数(ADC)值。为了分析几何变形,在B-1000 DWIS和T2加权Turbo旋转回波图像上测量从左到右和从左右前列腺的前列腺的直径。使用Wilcoxon等级测试进行比较差异,用于定性参数,方差分析和弗里德曼测试进行定量参数。 P值小于0.05被认为是显着的,具有多种比较的校正。 Udresults:Intereader协议对于所有定性特征的优异(脑内相关系数,0.71-0.79)很好。关于“分辨率”的主观图像质量比RS-EPI(平均浪潮得分,4.25 Vs 3.8; P = 0.031)和STX-EPI(4.25 Vs 3.3; P = 0.046)和ISHIM-EPI的SS-EPI与RS-EPI(4.4 Vs 3.8; P = 0.031)和STX-EPI(4.4 Vs 3.3; P = 0.047)相比。关于胶囊分界和区内解剖学没有显着差异。 ISHIM-EPI的信噪比比STX-EPI显着高(SNR±标准偏差[SD],28.13±8.21 Vs 14.96±2.4; P = 0.015)。 STX-EPI中的外周区的ADC值低于SS-EPI(ADC±SD,1002.94±83.51 Vs 1165.05±115.64; p = 0.013)和RS-EPI(1002.94±83.51 Vs 1244.40±89.95 ; p = 0.0012)和在STX-EPI的过渡区中,与RS-EPI(874.50±200.72 Vs 1261.47±179.23; p = 0.0021)。所有DWI序列之间的几何畸变没有统计学上显着的差异。 UDConclusions:单次旋转回声EPI和ISHIM-EPI与RS-EPI和STX-EPI相比,对卓越的图像质量和SNR表示没有显着差异在几何失真。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号