首页> 外文OA文献 >Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series
【2h】

Custom-made 3D printed subperiosteal titanium implants for the prosthetic restoration of the atrophic posterior mandible of elderly patients: a case series

机译:定制的3D印刷亚镜硫型钛植入者,用于老年患者萎缩性颌骨颌骨的假体恢复:案例系列

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Purpose To present the application of custom-made 3D-printed subperiosteal implants for fixed prosthetic restoration of the atrophic posterior mandible of elderly patients. Methods Between January 2017 and June 2018, all partially edentulous patients aged over 65 years, with two or more missing teeth in the posterior atrophic mandible, and who did not want to undergo bone regenerative procedures, were included in this study. These patients were rehabilitated with custom-made subperiosteal implants, designed from cone beam computed tomography (CBCT) and fabricated in titanium by means of direct metal laser sintering (DMLS). The outcome measures were fit and stability of the implants at placement, duration of the intervention, implant survival, and early and late complications. All patients were followed for 1 year after surgery. Results Ten patients (four males, six females; mean age 69.6, SD ± 2.8, median 69, 95% CI 67.9–71.6) were included in the study. The fit of the implants was satisfactory, with a mean rating of 7 out of 10 (SD ± 1.6, median 7, 95% CI 6–8). Only two implants had insufficient fit, because of the presence of scattering in the CBCT; however, they were adapted to the sites during the interventions. The mean duration of the intervention was 44.3 min (SD ± 19.4, median 37, 95% CI 32.3–56.3). At the one-year follow-up, no implants were lost (survival rate 100%). One implant presented immediate postoperative complications with pain, discomfort and swelling, and two patients experienced late complications, having their provisional restorations fractured during the temporisation phase. All these complications were minor in nature, but the final complication rate amounted to 30% (three of ten patients). Conclusions Although this study has limits (small patient sample and short follow-up), DMLS has proven to be an effective method for fabricating accurate subperiosteal implants, with high survival rates. This may represent an alternative treatment procedure in elderly patients with a severely atrophic posterior mandible, since it allows avoidance of regenerative bone therapies. Further studies are needed to confirm these outcomes.
机译:摘要目的,介绍定制的3D印刷亚脑膜植入物的应用,用于老年患者的萎缩后颌骨颌骨衰退的固定假体恢复。方法2017年1月至2018年6月,所有部分薄弱的患者65岁以上,在这项研究中包含两种或更多的牙齿,并且不想接受骨再生程序的牙齿。这些患者用定制的亚透镜植入物恢复,由锥形束计算机断层扫描(CBCT)设计,并通过直接金属激光烧结(DMLS)在钛中制造。结果措施适应和植入物的放置,干预持续时间,植入生存和早期并发症的植入物。所有患者均在手术后1年后进行。结果十名患者(四名男性,六名女性;平均年龄为69.6,SD±2.8,中位数69,95%CI 67.9-71.6)。植入物的适合令人满意,平均等级为10分,10分(SD±1.6,中位数7,95%CI 6-8)。由于在CBCT中存在散射,只有两个植入物不足。然而,它们在干预期间适应了地点。干预的平均持续时间为44.3分钟(SD±19.4,中位数37,95%CI 32.3-56.3)。在一年的随访中,没有植入物(存活率100%)。一只植入物呈现出直接术后并发症的疼痛,不适和肿胀,两名患者经历了晚期并发症,在临时阶段期间具有临时修复部分。所有这些并发症都有轻微的,但最终并发症率为30%(十名患者中的三个)。结论虽然本研究具有限制(小患者样品和短暂的随访),但DMLS已被证明是制造精确的亚眠植入物的有效方法,具有高存活率。这可以代表老年患者患有严重萎缩的后颌骨患者的替代治疗程序,因为它允许避免再生骨疗法。需要进一步的研究来确认这些结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号