首页> 外文OA文献 >Comparison of Respiratory Pathogen Detection in Upper versus Lower Respiratory Tract Samples Using the BioFire FilmArray Respiratory Panel in the Immunocompromised Host
【2h】

Comparison of Respiratory Pathogen Detection in Upper versus Lower Respiratory Tract Samples Using the BioFire FilmArray Respiratory Panel in the Immunocompromised Host

机译:使用生物传染性胶片呼吸呼吸道在免疫功能性主体中对呼吸道病原体检测的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background. The FilmArray Respiratory Panel (FARP) (BioFire Diagnostics, Inc.) is a multiplex, polymerase chain reaction (PCR) technique that can detect 17 respiratory viruses and 3 bacterial targets in a single reaction. Immunocompromised hosts (ICH) with respiratory illnesses often undergo bronchoscopy with bronchoalveolar lavage (BAL). This prospective study aimed to evaluate the yield and concordance of NP and BAL FARP testing when performed on the same patient concurrently. Methods. From February to December 2016, 125 patients (100 ICH and 25 non-ICH) were enrolled. NP swabs and BAL samples were sent for FARP testing. Results. The yield of the BAL FARP among ICH and non-ICH was 24% (24/100) and 8% (2/25), respectively. The yield of positive NP swabs in ICH was 27% (27/100) versus 4% (1/25) in non-ICH. The majority of patients (89%; 111/125) had concordant results between NP and BAL specimens. Of the 24 ICH patients who had a positive BAL FARP, the majority (79%) had the same pathogen detected from the NP swab. Conclusion. The FARP may be useful in the ICH. Given the high concordance, in patients whom a pathogen is identified on the NP FARP, a FARP performed on BAL will likely yield the same result. However, if the NP FARP is negative, performing the test on a BAL sample may have an incremental yield.
机译:背景。电影阵列呼吸面板(FARP)(Biofire Diagnostics,Inc。)是一种多重聚合酶链反应(PCR)技术,可在单一反应中检测17个呼吸道病毒和3种细菌靶标。免疫疾病患者(ICH)呼吸疾病经常与支气管肺泡灌洗(BAL)进行支气管镜检查。这种前瞻性研究旨在在同时对同一患者进行时评估NP和BAL Farp测试的产量和一致性。方法。从2016年2月到12月,注册了125名患者(100 ich和25个非Ich)。 NP拭子和BAL样品被送到FARP测试。结果。 ICH和非ICH之间的BAL Farp的产量分别为24%(24/100)和8%(2/25)。 ICH中阳性NP拭子的产量为27%(27/100),而非ICH中的4%(1/25)。大多数患者(89%; 111/125)在NP和BAL样本之间具有一致性的结果。在具有阳性BARP的24例患者中,大多数(79%)从NP拭子中检测到相同的病原体。结论。光栅可能在ICH中有用。鉴于高一致性,在患者在NP Farp上识别出一种病原体,对BAL执行的FARP可能会产生相同的结果。但是,如果NP Farp是负的,则对BAL样品进行测试可能具有增量产量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号