BACKGROUND:The topical HIV prevention (microbicides) field is in acute need of a method to rapidly and objectively measure adherence to product use in clinical trials. Infrared (IR) spectroscopy has been used in many pharmaceutical and forensic applications but has yet to be applied to adherence monitoring. In this study, we report on efforts to test the feasibility of using IR spectroscopy as a means to measure residual active or placebo vaginal product, semen exposure and vaginal insertion from a single swab. METHODS:A portable IR spectrometer equipped with diamond attenuated total reflectance (ATR) was used to capture spectra of unused vs. vaginally-used swabs, vaginal swabs containing semen, and vaginal swabs to which either tenofovir-containing or matching placebo products (vaginal gel or insert) were added. Spectral data obtained from swabs placed directly on the spectrometer were divided into calibration and testing sets for developing and validating discriminant models set up to provide yes/no predictions of: vaginal vs. non-vaginal use, presence vs. no presence of each test product, and presence vs. no presence of semen. Further validation of models was performed using vaginal swabs collected from a clinical study evaluating vaginally administered placebo insert formulations. RESULTS:For each discriminant model developed to predict vaginal vs. non-vaginal use, presence vs. no presence of each test product, and presence vs. no presence of semen, classified validation samples not included in the model development were correctly identified into their respective classes with minimal prediction error. Clinically obtained vaginal swabs collected 15-60 minutes after placebo insert use were also correctly identified, further validating the models. CONCLUSION:Our findings demonstrate the proof of concept that IR spectroscopy can be a method for rapid detection and characterization of microbicide products and biological fluids present in vaginal swabs. This novel method has potential to support real-time, on-site adherence monitoring in clinical or field settings.
机译:背景:局部艾滋病毒预防(杀微生物胶质剂)场是急性需要一种迅速和客观地测量在临床试验中对产品使用的依从性的方法。红外线(IR)光谱已经用于许多药物和法医应用,但尚未适用于依从性监测。在这项研究中,我们报告了测试使用IR光谱学的可行性作为测量残留活性或安慰剂阴道产物,精液暴露和阴道插入的手段。方法:配备有金刚石的便携式IR光谱仪,用于捕获未使用的与阴道用过的拭子,阴道拭子的阴道拭子,阴道拭子和阴道拭子的光谱谱谱仪捕获,与含有替诺福韦或匹配的安慰剂产品(阴道凝胶或插入)加入。从直接放置在光谱仪上的拭子获得的光谱数据被分为校准和测试集,用于开发和验证设置的判别模型,以提供是/否的预测:​​阴道与非阴道使用,存在与每个测试产品没有存在。 ,并且存在与没有精液。使用从从临床研究中收集的阴道拭子进行的阴道拭子进行进一步验证,评估阴道施用的安慰剂插入制剂。结果:对于预测阴道与非阴道使用的每个判别模型,存在与每种测试产物的存在,并且存在与没有细藻的存在,没有包含在模型开发中的分类验证样本被正确地识别到其上具有最小预测误差的相应类。临床上获得的阴道拭子15-60分钟也被正确识别,进一步验证了模型。结论:我们的研究结果证明了IR光谱可以是用于快速检测和表征微生物剂产品和阴道拭子的生物液的方法的证据。这种新颖的方法有可能在临床或现场设置中进行实时,现场依从性监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号