摘要

Objectives. The measurement of mucociliary transport velocity by rhinoscintigraphy with Tc-99m-macroaggregated albumin (99mTc-MAA) is reliable measure of mucociliary clearance. The aim of this study is to assess the intratest, interobserver, and intraobserver reproducibility of nasal mucociliary transport rate (NMTR) measurement. Materials and Methods. Twenty-two subjects were evaluated to determine intratest reproducibility and a group of 35 subjects was examined to determine inter- and intraobserver reproducibility. Rhinoscintigraphy with 99mTc-MAA was used to measure NMTR in all study subjects. Paired NMTR measurements were compared using a range of statistical methodologies. Intraclass correlation coefficients (ICC) and repeatability coefficients and Bland-Altman plots were applied to assess the degree of intratest, interobserver, and intraobserver variation. Results. Statistical analysis of test and retest experiments demonstrated the statistical equivalence of intratest NMTR measurements, interobserver NMTR measurements, and intraobserver NMTR measurements. The intratest ICC, interobserver ICC, and intraobserver ICC were 0.96, 0.83, and 0.91, respectively, indicating that intratest and intraobserver reproducibility are excellent and interobserver reproducibility is good. Conclusions. Rhinoscintigraphy using 99mTc-MAA results in highly reproducible measurement of NMTR. The use of radionuclide imaging in measuring NMTR results in excellent intratest and intraobserver reproducibility and good interobserver reliability.
机译:目标。用TC-99M-大基化白蛋白(99MTC-MAA)对鼻腔杂交的粘液输送速度的测量是可靠的粘液间隙测量。本研究的目的是评估鼻粘蛋白杂交运输速率(NMTR)测量的居内,interobserver和intraobserver再现性。材料和方法。评估了22个受试者以确定居内再现性,并检查一组35个受试者,以确定和中外机制的再现性。 99MTC-MAA的rhinospintigraphy用于测量所有研究科目的NMTR。使用一系列统计方法进行比较配对的NMTR测量。内相关系数(ICC)和可重复性系数和布兰德-Altman图被应用到评估intratest的程度,观察者间,和观察者的变化。结果。测试和重新测试的统计分析证明了IntrAtne NMTR测量,Interobserver NMTR测量和IntraObserver NMTR测量的统计等效性。的intratest ICC,观察者间ICC,和观察者ICC分别为0.96,0.83,和0.91,分别表明intratest和观察者再现性是优异的和观察者间的再现性良好。结论。使用99MTC-MAA的rhinospIntaphy导致NMTR的高度可重复测量。放射性核素成像在测量NMTR中的使用导致优异的难以居高学和初中的再现性和良好的Interobserver可靠性。

著录项

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号