首页> 外文OA文献 >Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome
【2h】

Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome

机译:闭合运动链上肢稳定性测试(CKCUES测试):对有或没有肩部撞击综合征的人进行的可靠性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: the Close Kinetic Chain Upper Extremity Stability Test (CKCUES test) is a low cost shoulder functional test that could be considered as a complementary and objective clinical outcome for shoulder performance evaluation. However, its reliability was tested only in recreational athletes' males and there are no studies comparing scores between sedentary and active samples. the purpose was to examine inter and intrasession reliability of CKCUES Test for samples of sedentary male and female with (SIS), for samples of sedentary healthy male and female, and for male and female samples of healthy upper extremity sport specific recreational athletes. Other purpose was to compare scores within sedentary and within recreational athletes samples of same gender.Methods: A sample of 108 subjects with and without SIS was recruited. Subjects were tested twice, seven days apart. Each subject performed four test repetitions, with 45 seconds of rest between them. the last three repetitions were averaged and used to statistical analysis. Intraclass Correlation Coefficient ICC2,1 was used to assess intrasession reliability of number of touches score and ICC2,3 was used to assess intersession reliability of number of touches, normalized score, and power score. Test scores within groups of same gender also were compared. Measurement error was determined by calculating the Standard Error of the Measurement (SEM) and Minimum detectable change (MDC) for all scores.Results: the CKCUES Test showed excellent intersession reliability for scores in all samples. Results also showed excellent intrasession reliability of number of touches for all samples. Scores were greater in active compared to sedentary, with exception of power score. All scores were greater in active compared to sedentary and SIS males and females. SEM ranged from 1.45 to 2.76 touches (based on a 95% CI) and MDC ranged from 2.05 to 3.91 (based on a 95% CI) in subjects with and without SIS. At least three touches are needed to be considered a real improvement on CKCUES Test scores.Conclusion: Results suggest CKCUES Test is a reliable tool to evaluate upper extremity functional performance for sedentary, for upper extremity sport specific recreational, and for sedentary males and females with SIS.
机译:背景:近端运动链上肢稳定性测试(CKCUES测试)是一种低成本的肩部功能测试,可以作为肩部性能评估的补充和客观临床结果。但是,仅在娱乐性运动员的男性中测试了其可靠性,尚无关于比较久坐和活动样本得分的研究。目的是检查CKCUES测试的久坐和停坐期间使用SIS的久坐的男性和女性的样本,久坐的健康的男性和女性的样本以及健康的上肢运动专用休闲运动员的男性和女性的样本。另一个目的是比较同性别的久坐者和休闲运动员样本中的得分。方法:招募了108名有和没有SIS的受试者。受试者接受了两次测试,相隔7天。每个受试者进行四次测试重复,两次之间休息45秒。将最后三个重复进行平均,并用于统计分析。类内相关系数ICC2,1用于评估触摸次数的会话间可靠性,而ICC2,3用于评估触摸次数,归一化分数和功效得分的会话间可靠性。相同性别的小组内的考试成绩也进行了比较。通过计算所有分数的测量标准误差(SEM)和最小可检测变化(MDC)来确定测量误差。结果:CKCUES测试显示所有样本的分数均具有极好的会话间可靠性。结果还显示,所有样品的触摸次数均具有出色的会话间可靠性。活动能力得分比久坐运动得分高,除力量得分外。与久坐和SIS的男性和女性相比,活动中的所有分数都更高。在有和没有SIS的受试者中,SEM的触觉范围为1.45至2.76(基于95%CI),MDC的范围为2.05至3.91(基于95%CI)。结论:结果表明,CKCUES Test是评估久坐,上肢特定运动休闲,以及久坐的男女久坐的上肢功能表现的可靠工具,至少需要三点触摸才能真正改善CKCUES测试得分。 SIS。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号