首页> 外文OA文献 >Le polyéthylène hautement réticulé de deuxième génération dopé à la vitamine E versus conventionnel dans l’arthroplastie totale de hanche. Étude prospective randomisée à 4ans minimum de recul
【2h】

Le polyéthylène hautement réticulé de deuxième génération dopé à la vitamine E versus conventionnel dans l’arthroplastie totale de hanche. Étude prospective randomisée à 4ans minimum de recul

机译:在总髋关节置换术中具有常规与维生素E的第二代掺杂的高度交联聚乙烯。随机预期研究4年来最低衰退

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this prospective randomized study was to compare the minimum 3-­year follow-­ up penetration of cementless polyethylene sockets of the same design in two configurations in a consecutive series of total hip arthroplasty.Between May 2010 and May 2011, 100 patients (100 hips) with a mean age of 70.8 ± 7.5 years were randomized (power of 80%, alpha of 5%) to receive either vitamin E doped highly cross-­ linked (group Vitamys, 0.1% vitamin E blended, 10 Mrads of gamma radiation, 50 hips) or moderately cross‐linked (group RM, 3 Mrads of gamma radiation in nitrogen, 50 hips) material. The cementless polyethylene cups were coated with pure titanium particles. All other parameters, including the 28 mm diameter metal femoral head, stem, surgical approach and postoperative course were identical in both groups. The primary criterion for evaluation was linear head penetration measurement, using the Martell system, performed by an investigator blinded to the polyethylene type. Both creep and steady state wear were measured.At the time of the minimum 3-­year follow-­up evaluation, 34 hips in the Vitamys group and 32 hips in the RM group have had complete data available for analysis (median follow‐up of 3.02 and 3.13 years, respectively). The median creep measured 0.02 mm versus 0.3 in the Vitamys and RM groups, respectively (Mann-­Whitney, p=0.04). The median steady state penetration rate from one year onwards was ‐0.097 mm/year in the Vitamys group versus 0.064 mm/year in the RM group (Mann and Whitney test, p=0.04). No complication specific to the material was recorded, and no patient was revised because of wear and/or osteolysis.This study provides the first randomized in vivo wear measurements of Vitamin E doped highly cross-­linked acetabular components. These early 3-­year follow-­up results demonstrated encouraging wear performance of vitamin E blended highly cross-­linked polyethylene. Longer term follow-­up is necessary to monitor the performance of these devices.
机译:这项前瞻性随机研究的目的是比较2010年5月至2011年5月连续100例(100例,100例,100例,100例)髋关节)平均年龄为70.8±7.5岁(功效为80%,α为5%),随机接受维生素E掺杂的高度交联的维生素A组(维生素组,混合0.1%的维生素E,10 Mrads的伽马射线辐射, 50髋)或中度交联(RM组,氮气中3 Mrads的伽马射线,50髋)材料。非水泥聚乙烯杯涂有纯钛颗粒。两组的所有其他参数,包括直径28 mm的金属股骨头,茎,手术入路和术后过程均相同。评估的主要标准是使用Martell系统进行的线性头穿透测量,该方法由对聚乙烯类型不了解的研究人员进行。测量蠕变和稳态磨损。在至少三年的随访评估中,Vitamys组的34髋和RM组的32髋具有完整的数据可用于分析(中位随访为3.02和3.13年)。中值蠕变测量值为0.02 mm,而Vitamys和RM组分别为0.3(Mann-­Whitney,p = 0.04)。从一年开始,Vitamys组的稳态渗透中位数为-0.097 mm /年,而RM组为0.064 mm /年(Mann和Whitney检验,p = 0.04)。没有记录到该材料的并发症,也没有因磨损和/或骨溶解而对患者进行矫正。这项研究首次提供了维生素E掺杂的高度交联髋臼组件的体内随机测量。这些为期3年的早期随访结果表明,维生素E共混高交联聚乙烯的磨损性能令人鼓舞。为了监视这些设备的性能,需要进行长期的后续跟踪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号