Diagnostic accuracy of 13N-ammonia PET, 11C-methionine PET and 18F-fluorodeoxyglucose PET: a comparative study in patients with suspected cerebral glioma

机译:13N-氨宠物,11C-甲硫氨酸PET和18F-氟脱氧葡萄糖PET的诊断准确率:疑似脑胶质瘤患者的比较研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background The treatment of patients with glioma depended on the nature of the lesion and on histological grade of the tumor. Positron emission tomography (PET) using 13N-ammonia (NH3), 11C-methionine (MET) and 18F-fluorodeoxyglucose (FDG) have been used to assess brain tumors. Our aim was to compare their diagnostic accuracies in patients with suspected cerebral glioma. Methods Ninety patients with suspicion of glioma based on previous CT/MRI, who underwent NH3 PET, MET PET and FDG PET, were prospectively enrolled in the study. The reference standard was established by histology or clinical and radiological follow-up. Images were interpreted by visual evaluation and semi-quantitative analysis using the lesion-to-normal white matter uptake ratio (L/WM ratio). Results Finally, 30 high-grade gliomas (HGG), 27 low-grade gliomas (LGG), 10 non-glioma tumors and 23 non-neoplastic lesions (NNL) were diagnosed. On visual evaluation, sensitivity and specificity for differentiating tumors from NNL were 62.7% (42/67) and 95.7% (22/23) for NH3 PET, 94.0% (63/67) and 56.5% (13/23) for MET PET, and 35.8% (24/67) and 65.2% (15/23) for FDG PET. On semi-quantitative analysis, brain tumors showed significantly higher L/WM ratios than NNL both in NH3 and MET PET (both P < 0.001). The sensitivity, specificity and the area under the curve (AUC) by receiver operating characteristic (ROC) analysis, respectively, were 64.2, 100% and 0.819 for NH3; and 89.6, 69.6% and 0.840 for MET. Besides, the L/WM ratios of NH3, MET and FDG PET in HGG all significantly higher than that in LGG (all P < 0.001). The predicted (by ROC) accuracy of the tracers (AUC shown in parentheses) were 86.0% (0.896) for NH3, 87.7% (0.928) for MET and 93.0% (0.964) for FDG. While no significant differences in the AUC were seen between them. Conclusion NH3 PET has remarkably high specificity for the differentiation of brain tumors from NNL, but low sensitivity for the detection of LGG. MET PET was found to be highly useful for detection of brain tumors. However, like FDG, high MET uptake is frequently observed in some NNL. NH3, MET and FDG PET all appears to be valuable for evaluating the histological grade of gliomas.
机译:摘要背景治疗胶质瘤患者依赖于病变的性质和肿瘤的组织学等级。使用使用13N-氨(NH3),11C-甲硫氨酸(MET)和18F-氟脱氧氧(FDG)的正电子发射断层扫描(PET)用于评估脑肿瘤。我们的目的是比较疑似脑胶质瘤患者的诊断准确性。方法九十患者根据先前的CT / MRI怀疑胶质瘤,曾经进行过NH3宠物,宠物和FDG宠物,在研究中进行了预期。参考标准由组织学或临床和放射性跟进建立。通过使用病变到正常的白质吸收比(L / WM比率)来解释图像通过视觉评估和半定量分析来解释。结果最后,诊断出30种高级胶质瘤(HGG),27个低级胶质瘤(LGG),10个非胶质瘤肿瘤和23例非肿瘤病变(NNL)。关于患有NNL的肿瘤的视觉评估,敏感性和特异性为NH3 PET的62.7%(42/67)和95.7%(22/23),94.0%(63/67)和56.5%(13/23)用于达到宠物和FDG PET的35.8%(24/67)和65.2%(15/23)。在半定量分析上,脑肿瘤比NH3中的NNL显着更高的L / WM比率,并达到PET(P <0.001)。通过接收器操作特征(ROC)分析的曲线(AUC)下的敏感性,特异性和面积分别为64.2,100%和0.819; 89.6,69.6%和0.840人。此外,NH3的L / WM比率为HGG的L / WM比率,全部高于LGG(所有P <0.001)。所预测的(通过ROC)的示踪剂(括号中的AUC)的精度为NH 3,87.7%(0.928)的86.0%(0.896),均为FDG的93.0%(0.964)。虽然它们之间没有在ach中没有显着差异。结论NH3 PET对来自NNL的脑肿瘤的分化具有显着性高特异性,但对LGG检测的敏感性低。发现宠物被发现对脑肿瘤的检测非常有用。然而,与FDG一样,在一些NNL中经常观察到高满足的摄取。 NH3,MET和FDG PET似乎对评估胶质瘤的组织学等级具有重要价值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号