首页> 外文OA文献 >Comparison of Esterman disability scores obtained using Goldmann perimetry and the Humphrey field analyzer in Japanese low-vision patients
【2h】

Comparison of Esterman disability scores obtained using Goldmann perimetry and the Humphrey field analyzer in Japanese low-vision patients

机译:在日本低远患者中使用Goldmann Perimetry和Humphrey Field Analyzer获得的esterman残疾分数的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PURPOSE:To compare the Esterman Disability Score (EDS) obtained with Goldmann perimetry (GP) testing and the Humphrey field analyzer (HFA) in low vision Japanese subjects. Subjects were also divided into groups by diagnosis to examine how disease influences EDS measurements. METHODS:The EDS was obtained using GP (GP-EDS) and the built-in testing program of the HFA (HFA-EDS). Tests were performed within 3 months of each other. Regression analyses were used to examine the relationship between GP-EDS and HFA-EDS. RESULTS:A total of 128 visually impaired subjects were included in this study. Subjects had low vision because of glaucoma (57 subjects), age-related macular degeneration (AMD, 17 subjects), retinitis pigmentosa (RP, 17 subjects), and other causes (37 subjects). The GP-EDS obtained was well-correlated with HFA-EDS (r = 0.87, P < 0.001) and it was possible to estimate HFA-EDS from GP-EDS. The GP-EDS was significantly lower than the HFA-EDS in eyes with glaucoma and RP. There was no significant difference between EDS values in eyes with AMD or other disease. CONCLUSION:The GP-EDS correlated well with the HFA-EDS. However, the relationship between the EDS measured with the two different testing modalities varies by disease.
机译:目的:将eSterman残疾人评分(EDS)与Goldmann Perimetry(GP)测试和低视野日本受试者的汉弗莱野外分析仪(HFA)进行比较。受试者还通过诊断分为组,以检查疾病如何影响EDS测量。方法:使用GP(GP-EDS)和HFA(HFA-EDS)的内置测试程序获得EDS。测试在彼此的3个月内进行。回归分析用于检查GP-EDS和HFA-EDS之间的关系。结果:本研究中纳入了总共128名视障科目。由于青光眼(57个受试者),年龄相关的黄斑变性(AMD,17个受试者),视网膜炎(RP,17个受试者)和其他原因(37个受试者),受试者具有低视力。获得的GP-ED与HFA-EDS良好相关(r = 0.87,p <0.001),可以估计来自GP-ED的HFA-EDS。 GP-EDS显着低于眼睛中的HFA-EDS和rp。 AMD或其他疾病的眼中的EDS值与EDS值之间没有显着差异。结论:GP-EDS与HFA-EDS相关。然而,用两种不同的测试方式测量的ED之间的关系因疾病而异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号