Multifocal visual evoked potentials provide a topographic measure of visual response amplitude and latency. The objective of this study was to evaluate the sensitivity and specificity of the multifocal visual evoked potential technique in detecting visual abnormalities in patients with multiple sclerosis. Multifocal visual evoked potentials were recorded from 74 patients with multiple sclerosis with history of optic neuritis (MS-ON, n = 74 eyes) or without (MS-no-ON, n = 71 eyes), and 50 normal subjects (controls, n = 100 eyes) using a 60-sector pattern reversal dartboard stimulus (VERIS). Amplitude and latency for each sector were compared with normative data and assigned probabilities. Size and location of clusters of adjacent abnormal sectors (p \u3c 0.05) were examined. Mean response amplitudes were (± SE) 0.39 ± 0.02, 0.53 ± 0.02, and 0.60 ± 0.01 for MS-ON, MS-no-ON, and control groups, respectively, with significant differences between all groups (p \u3c 0.0001). Mean latencies (ms; ±SE relative to normative data) were 12.7 ± 1.3 (MS-ON), 4.3 ± 1.1 (MS-no-ON), and 0.3 ± 0.4 (controls); group differences again significant (p \u3c 0.0001). Half the MS-ON eyes had clusters larger than five sectors compared with 13% in MS-no-ON and 2% in controls. Abnormal sectors were distributed diffusely, although the largest cluster was smaller than 15 sectors in two-thirds of MS-ON eyes. Cluster criteria combining amplitude and latency showed an area of 0.96 under the receiver operating characteristic curve, yielding a criterion with 91% sensitivity and 95% specificity. We conclude that the multifocal visual evoked potential provides high sensitivity and specificity in detecting abnormalities in visual function in multiple sclerosis patients.
机译:多焦点视觉诱发电位提供视觉反应幅度和潜伏期的地形测量。这项研究的目的是评估多焦点视觉诱发电位技术在检测多发性硬化症患者视觉异常中的敏感性和特异性。记录了74例具有视神经炎病史(MS-ON,n = 74眼)或无视神经炎史(MS-no-ON,n = 71眼)的多发性硬化症患者和50例正常受试者(对照组,n = 100眼),使用60扇区图案反转飞镖刺激(VERIS)。将每个扇区的幅度和等待时间与标准数据和分配的概率进行比较。检查了相邻异常扇区的簇的大小和位置(p <0.05)。 MS-ON,MS-no-ON和对照组的平均响应幅度分别为(±SE)0.39±0.02、0.53±0.02和0.60±0.01,所有组之间均存在显着差异(p \ u3c 0.0001)。平均时延(ms;相对于标准数据的±SE)为12.7±1.3(MS-ON),4.3±1.1(MS-no-ON)和0.3±0.4(对照);群体差异再次显着(p <0.0001)。一半的MS-ON眼的簇大于五个扇区,而MS-on-ON的眼球为13%,对照组为2%。异常扇区分散地分布,尽管在三分之二的MS-ON眼中最大的簇小于15个扇区。结合幅度和潜伏期的聚类标准显示出接收器工作特性曲线下的面积为0.96,从而产生了灵敏度为91%,特异性为95%的标准。我们得出的结论是,多灶性视觉诱发电位在检测多发性硬化症患者的视觉功能异常中提供了高灵敏度和特异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号