首页> 外文OA文献 >Intra-Tester Reliability and Concurrent Validity of Musculoskeletal Ultrasound and Vernier Calipre in Quantifying the Anteroposterior Diameter of the Common Extensor Origin of the Forearm and the Radial Nerve: A Cadaveric Study
【2h】

Intra-Tester Reliability and Concurrent Validity of Musculoskeletal Ultrasound and Vernier Calipre in Quantifying the Anteroposterior Diameter of the Common Extensor Origin of the Forearm and the Radial Nerve: A Cadaveric Study

机译:肌肉骨骼超声和游标卡利普雷在量化前臂和the神经共同伸肌起源的前后径中的测试仪内可靠性和并行有效性:一项尸体研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction: The literature reports an increase in anteroposterior diameter of the common extensor origin (CEO) of the extensor carpi radialis brevis (ECRB) and extensor digitorum communis (EDC) or the radial nerve in painful elbows diagnosed with lateral epicondylalgia (LE) or supinator syndrome. The edge-to-edge measurements of these anatomical structures are quantified using musculoskeletal ultrasound (MSUS). However, in the current literature, reports on the reliability and validity of MSUS measurements of the CEO (of ECRB and EDC) and the radial nerve are not found. In this study, reliability was measured for three testers in determining the anteroposterior diameter of the CEO (of ECRB and EDC) and the radial nerve. Moreover, the concurrent validity was determined of MSUS measurements with Vernier calipre measurements using formalin preserved elbows of human cadavers. Methodology: Cadaver measurements of the CEO (of ECRB and EDC) and the radial nerve were performed. Initially, the sonologist measured the anteroposterior diameter of the CEO (of ECRB and EDC) and the radial nerve. A month after scan, the formalin preserved cadavers were dissected. Consequently, the anteroposterior diameter of the exposed CEO (of ECRB and EDC) and the radial nerve was measured using the Vernier calipre. Results: Eight upper extremities of four embalmed Filipino cadavers (2 males: 2 females) were dissected. A total of seven (7) CEO of EDC, seven (7) CEO of ECRB, and eight (8) radial nerves at the level of the radial head in the elbows of four (4) cadavers were measured using the MSUS and the Vernier calipre. The MSUS and Vernier calipre protocol used in this study was found to be reliable, p u3e 0.05. However, in all three levels of interest, the MSUS measurements were statistically different from the Vernier calipre measurements, p u3c 0.05. Conclusion: MSUS and Vernier calipre measurements are reliable methods in measuring the CEO (of ECRB and EDC) and the radial nerve. While each of these methods is reliable in measuring the anteroposterior dimensions of the CEO (of the EDC and ECRB) and the radial nerve, substituting one for the other yielded statistically different measurement results.
机译:简介:文献报道,在诊断为外侧上con趾痛(LE)或旋后肌的疼痛肘部中,radial短腕伸肌(ECRB)和指趾伸肌(EDC)或the神经的普通伸肌起源(CEO)前后径增加综合症。使用肌肉骨骼超声(MSUS)对这些解剖结构的边缘到边缘测量进行量化。然而,在当前文献中,未找到关于CEO(ECRB和EDC)和the神经的MSSUS测量值的可靠性和有效性的报告。在这项研究中,测量了三名测试者在确定CEO(ECRB和EDC)和the神经前后直径时的可靠性。此外,使用福尔马林保存的人体尸体肘部,通过Vernier calipre测量值测定了MSUS测量值的同时有效性。方法:对CEO(ECRB和EDC)和the神经进行尸体测量。最初,超声医师测量了CEO(ECRB和EDC)和the神经的前后直径。扫描一个月后,解剖了福尔马林保存的尸体。因此,使用游标卡尺测量暴露的CEO(ECRB和EDC的)和the神经的前后直径。结果:解剖了四个防腐的菲律宾尸体的八个上肢(男性2例,女性2例)。使用MSUS和Vernier测量了四(4)具尸体肘部the骨头的水平,总共测量了七(7)名EDC首席执行官,七(7)名ECRB首席执行官和八(8)条radial神经。 calipre。发现本研究中使用的MSUS和Vernier calipre协议是可靠的,p≤0.05。但是,在所有三个感兴趣的级别中,MSUS测量值与Vernier calipre测量值在统计上都不同,p <0.05。结论:MSUS和游标卡尺测量是测量CEO(ECRB和EDC)和)神经的可靠方法。尽管这些方法中的每一种都可以可靠地测量CEO(EDC和ECRB)和the神经的前后尺寸,但用一种方法替代另一种方法在统计学上会产生不同的测量结果。

著录项

相似文献

  • 外文文献

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号