首页> 外文OA文献 >Anatomical variations of the innervated radial artery superficial palmar branch flap: A series of 28 clinical cases
【2h】

Anatomical variations of the innervated radial artery superficial palmar branch flap: A series of 28 clinical cases

机译:原子化桡动脉浅表性棕榈段分支皮瓣的解剖学变化:一系列28临床病例

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

Background The innervated radial artery superficial palmar branch (iRASP) flap was designed to provide consistent innervation by the palmar cutaneous branch of the median nerve (PCMN) to a glabrous skin flap. The iRASP flap is used to achieve coverage of diverse volar defects of digits. However, unexpected anatomical variations can affect flap survival and outcomes. Methods Cases in which patients received iRASP flaps since April 1, 2014 were retrospectively investigated by reviewing the operation notes and intraoperative photographs. The injury type, flap dimensions, arterial and neural anatomy, secondary procedures, and complications were evaluated. Results Twenty-eight cases were reviewed, and no flap failures were observed. The observed anatomical variations were the absence of a direct skin perforator, large-diameter radial artery superficial palmar branch (RASP), and the PCMN not being a single branch. Debulking procedures were performed in 16 cases (57.1%) due to flap bulkiness. Conclusions In some cases, an excessively large RASP artery was observed, even when there was no direct skin perforator from the RASP or variation in the PCMN. These findings should facilitate application of the iRASP flap, as well as any surgical procedures that involve potential damage to the PCMN in the inter-thenar crease region. Additional clinical cases will provide further clarification regarding potential anatomical variations.
机译:背景技术设计后的径向动脉表面跖跖(IRASP)襟翼旨在通过中位神经(PCMN)的露跖枝至无毛皮瓣提供一致的支配。 IRASP襟翼用于实现数字volar缺陷的覆盖率。然而,意外的解剖变异可以影响皮瓣存活和结果。方法通过2014年4月1日起,患者获得IRASP襟翼的病例通过审查操作说明和术中照片来回顾性研究。评估损伤型,皮瓣尺寸,动脉和神经解剖学,二次程序和并发症。结果审查了28例,没有观察过襟翼失败。观察到的解剖变化是不存在直接皮肤穿孔器,大直径径向动脉肤浅的凹痕分支(RASP),并且PCMN不是单个分支。由于襟翼散布度,在16例(57.1%)中进行了去保存程序。结论在某些情况下,即使没有从锉刀或PCMN中的变化没有直接的皮肤穿孔器,也会观察到过度大的锉动脉。这些发现应促进伊斯什襟翼的应用,以及任何涉及潜在损坏的局部折痕区域中PCMN的外科手术。额外的临床病例将在潜在的解剖学变异进一步澄清。

著录项

  • 作者

    Jae-Won Yang;

  • 作者单位
  • 年度 2020
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号