首页> 外文OA文献 >The effects of meteorological parameters and diffusive barrier reuse on the sampling rate of a passive air sampler for gaseous mercury
【2h】

The effects of meteorological parameters and diffusive barrier reuse on the sampling rate of a passive air sampler for gaseous mercury

机译:气象参数和扩散屏障的再利用对气态汞被动空气采样器采样率的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Passive air sampling of gaseous mercury (Hg) requires a highlevelof accuracy to discriminate small differences in atmosphericconcentrations. Meteorological parameters have the potential todecrease this accuracy by impacting the sampling rate (SR), i.e.,the volume of air that is effectively stripped of gaseous mercuryper unit of time. We measured the SR of a recently calibratedpassive air sampler for gaseous Hg in the laboratory under varyingwind speeds (wind still to 6 m s), temperatures (−15to +35 °C), and relative humidities (44 to80 %). While relative humidity has no impact on SR, SR increasesslightly with both wind speed (0.003 m dayincrease in SR or 2.5 % of the previously calibrated SR forevery m s increase for wind speeds   1 m s, typical of outdoor deployments) andtemperature (0.001 m day increase in SR or0.7 % for every 1 °C increase). The temperaturedependence can be fully explained by the effect of temperature onthe molecular diffusivity of gaseous mercury in air. Although theseeffects are relatively small, accuracy can be improved by adjustingSRs using measured or estimated temperature and wind speed data ator near sampling sites. We also assessed the possibility of reusingRadiello diffusive barriers previously used inthe passive air samplers. The mean rate of gaseous Hg uptake was notsignificantly different between new and previously used diffusivebarriers in both lab and outdoor deployments, irrespective of theapplied cleaning procedure. No memory effect fromRadiellos previously deployed in a high Hgatmosphere was observed. However, a loss in replicate precision forthe dirtiest Radiellos in the indoor experimentsuggests that cleaning is advisable prior to reuse.
机译:气态汞(Hg)的被动空气采样需要较高的精度才能区分大气浓度中的微小差异。气象参数有可能通过影响采样率(SR)(即每单位时间有效去除气态汞的空气量)来降低此精度。我们在实验室中测量了最近校准的被动式空气采样器的SR,该采样器在变化的风速(风仍为6 m s),温度(−15至+35 C)和相对湿度(44至80%)下进行了测试。尽管相对湿度对SR没有影响,但风速(> 1(m s时,风速(> 1 m s时,SR随风速(SR的0.003 m天增加或以前校准的SR的2.5%的每增加一秒)和温度(0.001 m SR的每日增加值或每增加1°C就会增加0.7%)。温度依赖性可以通过温度对空气中气态汞分子扩散率的影响来充分解释。尽管这些影响相对较小,但可以通过在采样点附近使用测得的或估算的温度和风速数据指示器调整SR来提高精度。我们还评估了重复使用以前在被动空气采样器中使用的雷迪洛扩散屏障的可能性。在实验室和室外环境中,无论采用何种清洁程序,新的和以前使用的扩散屏障之间的气态Hg吸收率均无显着差异。没有观察到先前部署在高大气层中的雷迪洛斯的记忆效应。但是,室内实验中最脏的Radiellos的重复精度会有所损失,这建议在重新使用之前建议进行清洁。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号