摘要

The new ground-based 22 GHz spectrometer, VESPA-22 (water Vapor Emission Spectrometer for Polar Atmosphere at 22 GHz) measures the 22.23 GHz water vapor emission line with a bandwith of 500 MHz and a frequency resolution of 31 kHz. The integration time for a measurement is of the order of hours, depending on season and weather conditions. Water vapor spectra are collected using the beam switching technique. VESPA-22 is designed to operate automatically with minimum need of maintenance; it employs an uncooled front-end characterized by a receiver temperature of about 180 K and its quasi-optical system presents a half power full beam angle of 3.5°. VESPA-22 measures also the sky opacity with a temporal resolution of two measurements an hour using the tipping curve technique. The instrument calibration is performed automatically by a noise diode; the emission temperature of this element is measured two times an hour through the observation of a black body at ambient temperature and of the sky at 60° of elevation. The retrieved profiles obtained inverting a 24-hour integration spectra present a sensitivity higher than 0.8 from about 25 to 72 km of altitude, a vertical resolution from about 12 to 23 km (depending on altitude) and an overall 1σ uncertainty between 5 and 12 %.In July 2016, VESPA-22 was installed at the THAAO (Thule High Arctic Atmospheric Observatory) located at Thule Air Base (76.5° N, 68.8° W), Greenland, and has been operating almost continuously since then, with very few interruption periods characterized by poor weather. The VESPA-22 water vapor mixing ratio vertical profiles discussed in this work cover the period from July 2016 to May 2017 and are compared with Version 4.2 of concurrent Aura/MLS (Waters et al., 2006) water vapor vertical profiles. In the sensitivity range of VESPA-22 retrievals, the intercomparison between the VESPA-22 dataset and Aura/MLS dataset convolved with VESPA-22 averaging kernels reveals a correlation coefficient of about 0.9 or higher and an average difference reaching its maximum of −6 % or −0.2 ppmv at the top of the sensitivity range.
机译:新的地面22 GHz光谱仪VESPA-22(用于22 GHz极地大气的水蒸气发射光谱仪)测量了22.23 GHz水蒸气发射线,其带宽为500 MHz,频率分辨率为31 kHz。测量的积分时间约为小时,具体取决于季节和天气条件。使用束切换技术收集水蒸气光谱。 VESPA-22旨在自动运行,而无需维护。它采用了未冷却的前端,其接收器温度约为180 K,其准光学系统的半功率全光束角为3.5°。 VESPA-22还使用倾翻曲线技术以每小时两次的时间分辨率来测量天空不透明度。仪器校准由噪声二极管自动执行。通过观察环境温度下的黑体和仰角60°的天空,每小时测量两次该元素的发射温度。反演24小时积分谱获得的反演轮廓表示,在大约25至72 km的高度上灵敏度高于0.8,在垂直分辨率下在12至23 km左右(取决于高度),且1σ总体不确定度在5至12%之间.2016年7月,VESPA-22被安装在格陵兰图勒空军基地(76.5°N,68.8°W)的THAAO(图勒高北极大气观测所)上,此后几乎一直连续运行,几乎没有中断天气恶劣的时期。这项工作中讨论的VESPA-22水蒸气混合比垂直剖面涵盖了2016年7月至2017年5月,并与4.2版同时进行的Aura / MLS(Waters等,2006)水蒸气垂直剖面进行了比较。在VESPA-22检索的敏感度范围内,将VESPA-22数据集与Aura / MLS数据集与VESPA-22平均内核进行卷积后的比对显示相关系数约为0.9或更高,并且平均差异达到最大-6%或-0.2 ppmv(在灵敏度范围的顶部)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号