Multiphase machines offer inherent tolerance to faults such as open converter legs (OCLs), which are especially frequent. Because of this reason, they are particularly attractive for applications where fault tolerance is important, such as offshore wind energy or aerospace, naval and military vehicles. It has been previously shown that, under an OCL, certain stator winding configurations (SWCs) different from star yield smaller stator copper loss (SCL) and larger maximum achievable torque (MAT) than star SWC for the same torque command and machine. This advantage comes just at the expense of a moderate increase in converter rating. However, only the case of single OCL was studied in general. The SCL, MAT and required converter rating for two OCLs are currently unknown for different combinations of phase number, faulted legs and SWCs. Actually, under two OCLs (unlike for one OCL) it may be possible to actively modify the order of the faulted/healthy legs to enhance the performance in these terms, but this possibility has not been studied so far in spite of its potential. This paper addresses the postfault performance of multiphase drives with two OCLs, for various SWCs. The MAT (derating factor), SCL and necessary converter rating are assessed in numerous possible scenarios. The most convenient alternatives are established. Most importantly, in view of the conclusions of this analysis, a novel method is proposed to improve substantially the MAT and SCL by actively altering the connections between the converter and machine terminals. Experimental results with six-phase and twelve-phase setups are provided.
机译:多相机器为诸如开放式转换器腿(OCL)等故障提供固有的容差,这尤其频繁。由于这个原因,它们对容错是重要的应用特别有吸引力,例如海上风能或航空航天,海军和军用车辆。先前已经表明,在OCL下,不同的定子绕组配置(SWC)不同于星产生较小的定子铜损失(SCL),并且比与星形SWC相同的扭矩指令和机器的最大可实现的扭矩(垫)。这一优势仅在于转换器评级的中等增长费用。但是,只有单一OCL的情况是一般的。对于两个OCL的SCL,MAT和所需的转换器等级目前未知相位数,断层腿和SWC的不同组合。实际上,在两个OCL下(与一个OCL不同),可能会主动修改故障/健康腿的顺序,以提高这些术语的性能,但是尽管有潜力,但尚未研究这种可能性。本文讨论了各种SWC的两个OCL的多相驱动器的后退性能。在许多可能的场景中评估垫子(降额因子),SCL和必要的转换器等级。建立了最方便的替代方案。最重要的是,鉴于该分析的结论,提出了一种新的方法,通过积极改变转换器和机器端子之间的连接来改善垫子和SCL的基本上。提供了具有六相和12个相设置的实验结果。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号