Inductively Coupled Plasma Mass Spectrometry as a Reference Method to Evaluate Serum Calcium Measurement Bias and the Commutability of Processed Materials during Routine Measurements

机译:电感耦合等离子体质谱作为评估血清钙测量偏差和处理材料在常规测量期间的可扩展性的参考方法

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: Measuring total serum calcium is important for the diagnosis of diseases. Currently, results from commercial kits for calcium measurement are variable. Generally, the performance of serum calcium measurements is monitored by external quality assessment (EQA) or proficiency testing schemes. However, the commutability of the EQA samples and calibrators is often unknown, which limits the effectiveness of EQA schemes. The aim of this study was to evaluate the bias of serum calcium measurements and the commutability of processed materials.Methods: Inductively coupled plasma mass spectrometry was applied as a comparative method, and 14 routine methods were chosen as test methods. Forty-eight serum samples from individual patients and 25 processed materials were quantified. A scatter plot was generated from patient samples, and 95% prediction intervals were calculated to evaluate the commutability of the processed materials and measurement bias at three concentration levels was used to determine the accuracy of routine assays.Results: All assays showed high precision (total coefficient of variation [CV] 0.99). For all assays, the mean bias for the 48 patient samples ranged from −0.13 mmol/L to 0.00 mmol/L (−5.61–0.01%), and the ranges for the three concentrations were −0.10–0.04 mmol/L (−5.71–2.35%), −0.14–−0.01 mmol/L (−5.80–−0.30%), and −0.19–0.04 mmol/L (−6.24–1.22%). The EQA samples, calibrators, and animal sera exhibited matrix effects in some assays; human serum pools were commutable in all assays; certificate reference materials were commutable in most assays, and only GBW09152 exhibited a matrix effect in one assay; and aqueous reference materials exhibited matrix effects in most assays.Conclusions: Biases for most assays were within the acceptable range, although the accuracy of some assays needs improvement. Human serum pools prepared from patient samples were commutable, and the other tested materials exhibited a matrix effect.
机译:背景:测量总血清钙对疾病的诊断非常重要。目前,用于钙测量的商业套件的结果是可变的。通常,通过外部质量评估(EQA)或能力测试计划来监测血清钙测量的性能。然而,EQA样品和校准器的可扩展性通常是未知的,这限制了EQA方案的有效性。本研究的目的是评估血清钙测量的偏差和加工材料的可扩展。方法:电感耦合等离子体质谱法作为对比方法施用,选择14例常规方法作为试验方法。量化来自个体患者和25种加工材料的四十八个血清样品。从患者样品产生散射图,计算95%的预测间隔以评估加工材料的可扩展,并使用三种浓度水平的测量偏压来确定常规测定的准确性。结果:所有测定结果都显示出高精度(总计变异系数[CV] 0.99)。对于所有测定,48例患者样品的平均偏压范围为-0.13mmol / L至0.00 mmol / L(-5.61-0.01%),并且三种浓度的范围为-0.10-0.04mmol / L(-5.71 -2.35%),-0.14--0.01 mmol / L(-5.80-0.30%),和-0.19-0.04 mmol / L(-6.24-1.22%)。 EQA样品,校准剂和动物血清在一些测定中表现出基质效应;人类血清池在所有测定中都会通货;证书参考资料在大多数测定中可通货,只有GBW09152在一个测定中表现出基质效应;并且水性参考材料在大多数测定中表现出基质效应。结论:大多数测定的偏差在可接受的范围内,尽管某些测定的准确性需要改善。从患者样品制备的人血清池可通货,其他测试材料表现出基质效应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号