Classification of Sleep Apnea Severity by Electrocardiogram Monitoring Using a Novel Wearable Device

机译:用新型可穿戴装置对睡眠呼吸暂停严重性的分类

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sleep apnea (SA) is a prevalent disorder diagnosed by polysomnography (PSG) based on the number of apnea−hypopnea events per hour of sleep (apnea−hypopnea index, AHI). PSG is expensive and technically complex; therefore, its use is rather limited to the initial diagnostic phase and simpler devices are required for long-term follow-up. The validity of single-parameter wearable devices for the assessment of sleep apnea severity is still debated. In this context, a wearable electrocardiogram (ECG) acquisition system (ECG belt) was developed and its suitability for the classification of sleep apnea severity was investigated using heart rate variability analysis with or without data pre-filtering. Several classification algorithms were compared and support vector machine was preferred due to its simplicity and overall performance. Whole-night ECG signals from 241 patients with a suspicion of sleep apnea were recorded using both the ECG belt and patched ECG during PSG recordings. 65% of patients had an obstructive sleep apnea and the median AHI was 21 [IQR: 7−40] h − 1 . The classification accuracy obtained from the ECG belt (accuracy: 72%, sensitivity: 70%, specificity: 74%) was comparable to the patched ECG (accuracy: 74%, sensitivity: 88%, specificity: 61%). The highest classification accuracy was obtained for the discrimination between individuals with no or mild SA vs. moderate to severe SA. In conclusion, the ECG belt provided signals comparable to patched ECG and could be used for the assessment of sleep apnea severity, especially during follow-up.
机译:睡眠呼吸暂停(SA)是一种基于的每小时睡眠呼吸暂停低通气事件(呼吸暂停低通气指数,AHI)的数量由多导睡眠图(PSG)确诊流行疾病。 PSG是昂贵,技术复杂;因此,它的使用是相当有限的初始诊断相位和所需的长期随访简单的设备。睡眠呼吸暂停的严重程度的评估单参数可穿戴式设备的有效性仍有争议。在此背景下,可佩戴心电图(ECG)采集系统(ECG带)的开发和使用心脏速率变异性分析用或不用数据预滤波其睡眠呼吸暂停的严重程度分级适应性进行了研究。几个分类算法进行比较,支持向量机被优选的,因为其简单性和整体性能。期间PSG记录使用ECG带和修补的ECG均来自241例患者全夜ECG信号与睡眠呼吸暂停的一个怀疑的记录。 65%的患者有阻塞性睡眠呼吸暂停并且平均AHI为21 [IQR:7-40 1 H - 1。从ECG带获得的分类精度(准确度:72%,灵敏度:70%,特异度:74%)是可比较的补丁的ECG(精度:74%,灵敏度:88%,特异度:61%)。获得最高的分类精度与无或轻度SA与个体之间的区别中度至重度SA。总之,ECG带提供媲美修补的ECG信号,可用于睡眠呼吸暂停的严重程度的评估,特别是随访期间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号