Vibratory cavitation erosion with vibratory and stationary specimens is studied for three materials in tap water at room temperature. The separation distance is varied from 0.127 to 6.096 mm. Test materials were commercially pure lead, soft (1100-O) aluminum and type 316 stainless steel. The double-horn amplitude was 58.4 [mu]m (2.3 x 10-3 in) in a 20 kHz facility. The total duration of all tests was 10 min.The weight loss of both vibratory and stationary specimens of course depends on materials. The weight loss of stationary specimens is best correlated as a function of the reciprocal of the separation distance.
机译:使用振动和固定标本进行振动空化腐蚀,在室温下自来水中的三种材料研究了三种材料。分离距离为0.127至6.096mm。试验材料是商业纯的铅,软(1100-O)铝,型316不锈钢。在20kHz设施中,双喇叭振幅为58.4μm(2.3×10-3英寸)。所有测试的总持续时间为10分钟。振动和固定标本的重量损失当然取决于材料。固定标本的重量损失与分离距离的往复式的函数最佳相关。