首页> 外文OA文献 >Accuracy of linear measurement in Galileos cone beam CT under simulated clinical condition
【2h】

Accuracy of linear measurement in Galileos cone beam CT under simulated clinical condition

机译:模拟临床条件下伽利斯锥梁CT线性测量的准确性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective : To determine if the linear measurements made in Galileos CBCT in the presence of soft tissue using cadaver heads are accurate.Materials and methods : CBCT images were obtained in Galileos CBCT device after placement of gutta percha markers, three to the facial and one to the lingual of the area of interest in the mandible. The CBCT orthoradial image showing perfect alignment of the lingual with a facial marker was selected as the plane of measurement. The distance between the most superior and most inferior point on the bone on the selected plane was measured electronically. The specimens were sectioned along this plane and physical measurements were obtained with digital calipers. Linear distance was measured between the most superior and most inferior point on the bone on the selected plane. This distance was measured in 6 specimens with calipers and compared to the distance measured on the corresponding CBCT images.Results: A paired-sample t-test was used to determine whether the mean difference measurement value of two measurements at right side was significantly equal to zero. The data revealed that overall there was no statistically significant difference between CBCT and Physical measurement on right side (p=0.2298), left side (p=0.3554) and overall between CBCT and Physical measuremnets (p=0.2684).Conclusions: Based on the statistical evaluation of the CBCT and Physical measurements it can be concluded that Galileos CBCT unit is reliable for evaluation of linear measurements between anatomic structures within the bone in the presence of soft tissues in the mandible specially for measuring height of available bone.
机译:目的:为了确定线性测量在GALILEOS CBCT使用尸体头是accurate.Materials和方法取得了软组织的存在:的杜仲胶标记物放置之后在GALILEOS CBCT设备获得CBCT图像,三到面部和一个在下颌感兴趣的区域的语言。示出具有面部标志舌的完美对准的CBCT图像orthoradial被选为测量的平面。以电子测量所选择的平面上的骨的最上部和最下点之间的距离。标本沿此平面切片,并用数显卡尺获得物理测量。对所选择的平面上的骨的最上部和最下点之间测得的直线距离。该距离是在6个样品测量用测径器,并与在相应的CBCT images.Results测量的距离:一个配对样本t检验用于确定在右侧两个测量值的平均值的差测定值是否为显著等于零。该数据表明,总有CBCT和上右侧物理测量法之间没有统计学显著差异(p = 0.2298),左侧(P = 0.3554)和总CBCT和物理measuremnets之间(P = 0.2684)。结论:基于在CBCT和物理测量的统计评估它可以得出结论,GALILEOS CBCT单元是可靠用于软组织的存在下在骨内的下颌骨的解剖结构之间的线性测量的评价专门用于测量可用的骨的高度。

著录项

  • 作者

    Rumpa Ganguly;

  • 作者单位
  • 年度 -1
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号