首页> 外文OA文献 >Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter)
【2h】

Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter)

机译:用不同屈光度间隔植入两种透镜后屈光结果的比较评价(0.25屈光度与0.50屈光度)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background Intraocular lenses (IOLs) with different diopter (D) intervals may have different tolerance, and may provide different accuracy of refractive outcome after cataract surgery. The aim of the study is to compare the accuracy of refractive outcome after implantation of IOLs with different D intervals after cataract surgery. Methods A total of 80 eyes from 40 patients who underwent phacoemulsification with implantation of a 0.50 D interval Akreos AO IOL in one eye and a 0.25 D interval Softec HD™ IOL in the other eye were enrolled. The percentages of eyes with refractive prediction error within ±0.50 D at one month after surgery were compared. To evaluate the effect of the dioptric errors of the IOL itself on refractive prediction error, the percentage of eyes with refractive prediction error within ±0.25 D of the IOL with a standard deviation (SD) of ±0.40 D was compared with that of the IOL with a SD of ±0.11 D through Monte Carlo simulations. Results In this clinical study, the percentage of eyes with refractive prediction error within ±0.50 D by the Haigis formula in the Softec HD™ group (85.0%) was significantly greater than that in the Akreos AO group (57.5%; P = 0.027). In Monte Carlo simulations, all percentages of eyes with refractive prediction error within ±0.25 D by the Haigis and SRK/T formulas in the Softec HD™ group were significantly greater than those in the Akreos AO group. Conclusions The IOL with a 0.25 D interval was more accurate than the IOL with a 0.50 D interval in predicting refractive outcome after cataract surgery. Trial registration Current Controlled Trials KCT0002192, Retrospectively registered (Date of registration: 6 January 2017).
机译:摘要背景与不同屈光度(d)间隔的眼镜透镜(IOL)可能具有不同的耐受性,并且可以在白内障手术后提供不同的屈光结果准确性。该研究的目的是比较在白内障手术后用不同的D间隔植入IOL后屈光结果的准确性。方法从一只眼中植入0.50d间隔AO IOL的术治疗术后40名患者的40名患者共有80只眼睛,另一种眼睛中的0.25d Intelledec HD TM IOL进行了注册。比较手术后一个月在±0.50 d内折射预测误差的眼睛百分比。为了评估IOL本身对折射预测误差的屈光误差的影响,与IOL的标准偏差(SD)的IOL±0.25d的折射预测误差内的眼睛百分比与IOL的百分比通过Monte Carlo模拟,SD为±0.11 d。结果在该临床研究中,Softec HD TM组中的HAIGIS公式(85.0%)中的折射预测误差±0.50d内的眼睛百分比明显大于Akreos AO组(57.5%; P = 0.027) 。在Monte Carlo模拟中,Softec HD™组HAIGIS和SRK / T配方中的折射预测误差的所有百分比均为折射预测误差明显大于AKREOS AO组中的折射率。结论具有0.25d间期的IOL比IOL更精确,在白内障手术后预测屈光结果的0.50 d间隔。试用登记当前受控试验KCT0002192,回顾性注册(注册日期:2017年1月6日)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号