首页> 外文OA文献 >Large-Volume Injection Electrothermal AAS Combined with Tungsten-treated Pyrolytic Graphite Furnace: Determination of Cadmium in Tap, Snow and River Water Samples with Phosphate Modifier
【2h】

Large-Volume Injection Electrothermal AAS Combined with Tungsten-treated Pyrolytic Graphite Furnace: Determination of Cadmium in Tap, Snow and River Water Samples with Phosphate Modifier

机译:大体积进样电热原子吸收光谱法与钨热解石墨炉相结合:磷酸盐改性剂测定自来水,雪和河水样品中的镉

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A large-volume (100 µl) injection-ETAAS with W-treated PG furnace combined with a phosphate modifier was applied to the determination of unpolluted levels of Cd in tap, snow and river-water samples. The limit of detection of 1.1 ng l^-1 was observed for a 4 w/v% NH_4H_2PO_4 modifer. Matrix interference studies were tested for major ion species well found in fresh water. The direct determination of Cd in certified river water (12 ± 2 ng l^-1) was carried out and the observed value was in agreement with the certified one. The good recoveries of Cd added to real environmental water samples were also observed. This method was applied to the determination of Cd in unpolluted environmental water samples.
机译:装有W处理的PG炉和磷酸盐改性剂的大体积(100 µl)注射ETAAS被用于测定自来水,雪和河水样品中Cd的未污染水平。对于4w / v%的NH_4H_2PO_4修饰剂观察到1.1ng l -1的检出限。测试了基质干扰研究中淡水中发现的主要离子种类。可以直接测定合格的河水中的镉(12±2 ng l ^ -1),其观测值与合格者一致。还观察到了添加到实际环境水样品中的镉的良好回收率。该方法用于环境污染水样中镉的测定。