Purpose: Three-dimensional (3D) conformal radiation therapy is the standard technique used for adjuvant breast radiation. We report the clinical use of a novel 6-MV flattening-filter-free O-ring linear accelerator (6X-FFF ORL) for breast cancer that may improve upon 3D conformal radiation therapy with its higher dose rate and faster rotation and leaf speed than traditional C-arm gantries. Methods and Materials: We retrospectively identified consecutive women with breast cancer who underwent surgery followed by radiation therapy to the breast or chest wall on Halcyon (Varian Medical Systems, Palo Alto, CA), a novel 6X-FFF ORL. We report their clinicopathologic information, radiation therapy details, acute toxicities, dose-volume histogram data, couch corrections, and treatment times. Results: Thirty-four women were treated for breast cancer on a 6X-FFF ORL between February 2018 and September 2018. All patients underwent lumpectomy (92%) or mastectomy (8%). Tumors were left sided in 44% and bilateral in 9%, and 9% included comprehensive nodal radiation therapy. Twelve percent of patients were treated prone and 29% with deep-inspiration breath hold. Standard target and normal-tissue constraints were met in nearly all plans. The 3D vector couch correction average was 0.77 ± 0.05 cm. The mean beam-on time was 2.0 ± 0.3 minutes, and mean treatment time from start of imaging to beam-off was 4.4 ± 0.4 minutes. Grade 2 dermatitis, fatigue, and breast pain occurred in 18%, 9%, and 3% of patients, respectively. Conclusions: In this first clinical report of breast radiation therapy with a 6X-FFF ORL, treatment was versatile and fast for complex setups and techniques, with acceptable toxicity and organ-at-risk doses. Thus, a 6X-FFF ORL can increase throughput or reduce length of day compared with a conventional C-arm linear accelerator in departments with a busy breast service.
机译:目的:三维(3D)保形放射治疗是用于佐剂乳房辐射的标准技术。我们报告了一种新型6-MV平坦滤纱O形环线性加速器(6x-FFF ORL)的临床应用,用于乳腺癌,可以改善3D共形放射疗法,其剂量率较高,旋转和叶速更快传统的C臂喇叭。方法和材料:我们回顾性地鉴定了患有乳腺癌的乳腺癌,然后接受手术,然后在哈西顿(Varian Medical Systems,Palo Alto,CA)上的乳房或胸壁上进行放射治疗,这是一种新的6x-FFF Orl。我们报告其临床病理信息,放射治疗细节,急性毒性,剂量群体数据,沙发校正和治疗时间。结果:2018年2月和2018年9月,在6倍FFF ORL上对乳腺癌进行了乳腺癌治疗了34名妇女。所有患者都接受了肿块切除术(92%)或乳房切除术(8%)。肿瘤留在44%和双侧9%,9%包括综合节点放射治疗。 12%的患者受到俯卧,29%的呼吸暂停。几乎所有计划都会满足标准目标和正常组织约束。 3D矢量沙发校正平均值为0.77±0.05厘米。平均光束时间为2.0±0.3分钟,并且从成像开始的平均处理时间为4.4±0.4分钟。 2级皮炎,疲劳和乳房疼痛分别发生18%,9%和3%的患者。结论:在乳腺辐射治疗的第一个临床报告中,用6x-FFF orl,治疗是通用的,复杂的设置和技术快速,具有可接受的毒性和风险危险剂量。因此,与具有繁忙乳房服务的常规C形臂线性加速器相比,6x-FFF ORL可以增加吞吐量或减少时间的长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号