The Acute And Sub-Acute Effects Of Electrosurgical And Ultrasonic Surgical Devices On The Neurophysiologic Changes Of Sciatic Nerve Function

机译:电外科和超声外科手术对坐骨神经功能神经生理变化的急性和亚急性作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

THE ACUTE AND SUB-ACUTE EFFECTS OF ELECTROSURGICAL AND ULTRASONIC SURGICAL DEVICES ON THE NEUROPHYSIOLOGIC CHANGES OF SCIATIC NERVE FUNCTION Since the dawn of medicine, blood loss during surgeries has been one of the major concerns for the surgeons. Iatrogenic blood loss can have several harmful effects on the patient condition. With the rapid development in technology, the blood loss can now be significantly minimized by using a variety of vessel sealing devices that use several energy sources to seal the blood vessels or tissue bundles instead of traditional sutures and clips. These devices can be used in several general, colorectal, gynecological and urological surgical procedures.The two types of vessel sealing techniques accepted worldwide are based on electrosurgical and ultrasonic technology. The electrosurgical technique uses electric energy while the ultrasonic technique uses ultrasonic energy to seal the blood vessels and simultaneously cut and coagulate tissues.In 2009, more than 17.5 million electrosurgical procedures were performed in US alone. Also, ultrasonic devices have been used for over 10 million procedures worldwide. However, it is not clear to if these devices can cause nerve injury when applied near the nerve tissue. The safe distance to apply these devices from nerves has not been profoundly investigated.In the current study, a set of electrosurgical and ultrasonic devices were surgically tested in a rat model. These devices were applied on the muscle tissue at specific distances from the sciatic nerve. The consequent change in the nerve conduction function was neurophysiologically assessed and analyzed. Also, a developmental study was performed to determine a feasible surgical technique to use these devices to minimize nerve injury in the acute as well as sub-acute phase. The sensory nerve function was assessed by means of behavioral changes in the sub-acute phase.It was seen that electrosurgical devices produced a significant nerve dysfunction as compared to the ultrasonic devices. The ultrasonic devices appeared to be more safe, convenient and efficient during surgical applications close to the nerve tissue.
机译:电外科和超声外科设备对坐骨神经功能的神经生理学变化的急性和亚急性作用自药物问世以来,手术期间的失血一直是外科医生关注的主要问题之一。医源性失血会对患者的病情产生多种有害影响。随着技术的飞速发展,现在可以通过使用各种使用多种能源而不是传统的缝合线和夹子来密封血管或组织束的血管密封装置,将出血量大大减少。这些设备可用于多种常规,大肠,妇科和泌尿外科手术程序。全世界接受的两种血管密封技术基于电外科和超声技术。电外科技术使用电能,而超声技术则使用超声能量密封血管并同时切割和凝结组织。仅在美国,2009年就进行了超过1750万次电外科手术。而且,超声波设备已在全球范围内用于超过一千万次手术。但是,尚不清楚这些设备在神经组织附近使用时是否会引起神经损伤。尚未深入研究使用这些设备与神经的安全距离。在当前研究中,在大鼠模型中对一组电外科和超声设备进行了手术测试。这些装置以距坐骨神经特定距离的方式应用于肌肉组织。通过神经生理学评估和分析神经传导功能的结果变化。此外,进行了一项开发研究,以确定一种可行的手术技术,以使用这些设备将急性期和亚急性期的神经损伤降至最低。通过亚急性期的行为改变来评估感觉神经功能。与超声波装置相比,电外科手术装置会产生明显的神经功能障碍。在外科手术中靠近神经组织的应用中,超声波装置似乎更加安全,方便和高效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号