Prediction of Harmonic Distortion in a Distribution SystemCaused by Housing Loads

机译:配电系统中谐波失真的预测由住房负荷引起

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract: This paper will discuss about impact ofnonlinearload in residential costumer to harmonic distortion.Electricityconsumerbehaviourparticularlyinthe household sectorwith the development oftechnology willevolve.Equipment usedforeveryday purposescontinues to growandhas become alifestyle.Themodern life isbecoming fabulous with the invention of new technology, so that many more electricity utilities are used bypeople and their houses in daily life. Nowadays, loads in the housing electricity utility do not onlycontain oflinier loads, but also non-linier loads such as television, computer, microwave, fluorescent lamp and so on. Theproblem usesnonlinearload is create harmonic distortion. The harmonic distortion will reduce the life time ofelectrical equipment and inefficiency. The purpose of this research is to domodellingand prediction ofharmonics level on housing electricity utility. Themodellingand prediction of this research was usingharmonicanalysiswith ETAP PowerStation version 4.0.0 C. This experiment was done in five houses as sample. Themeasurement was done on non-linier load and Kwh-meter in every house using Fluke 41B. The result ofmeasurement on Kwh-meter on houses was compared in order to get the analysis result for VTHD, ITHD,power factor and frequency. The results research showed that VTHD, power factor (PF) and frequency onhouse are comply to the normal standard. VTHD result (maximum 5) is1.1–3.6.Beside those, ITHD onhouse also comfortable to due standard, but there are housees that did not comply into the appointed standard.The analysis result showed that energy saving lamp cause the biggest harmonics level. The level of harmonics inevery house depends on how many electricity equipment used in it
机译:摘要:本文将讨论住宅用户中的非线性负载对谐波失真的影响。随着技术的发展,尤其是家庭用户的用电行为将发生演变。日常使用的设备继续发展并已成为一种生活方式。现代生活正随着新技术的发明而日渐盛行,因此更多的电力公用事业成为了人们的梦想。在日常生活中被人们及其房屋使用。如今,房屋电力公司的负载不仅包含线性负载,而且还包含非线性负载,例如电视,计算机,微波,荧光灯等。使用非线性负载的问题是产生谐波失真。谐波畸变将减少电气设备的使用寿命并降低效率。本研究的目的是对房屋用电的谐波水平进行建模和预测。使用ETAP PowerStation版本4.0.0 C进行谐波分析,对本研究进行建模和预测。该实验在五个房屋中作为样本进行。使用Fluke 41B对每个房屋的非直线负载和Kwh-meter进行了测量。比较了房屋用电度表的测量结果,以获得VTHD,ITHD,功率因数和频率的分析结果。结果研究表明,VTHD,功率因数(PF)和内部频率均符合正常标准。 VTHD结果(最多5个)为1.1到3.6。此外,ITHD机房也符合标准要求,但有些房屋不符合指定标准。分析结果表明,节能灯会产生最大的谐波水平。每个房屋的谐波水平取决于房屋中使用的电力设备数量

著录项

  • 作者

    Rohi Daniel;

  • 作者单位
  • 年度 2013
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号