abstract: We designed and evaluated an active sampling device, using as analytical targets a family of pesticides purported to contribute to honeybee colony collapse disorder. Simultaneous sampling of bulk water and pore water was accomplished using a low-flow, multi-channel pump to deliver water to an array of solid-phase extraction cartridges. Analytes were separated using either liquid or gas chromatography, and analysis was performed using tandem mass spectrometry (MS/MS). Achieved recoveries of fipronil and degradates in water spiked to nominal concentrations of 0.1, 1, and 10 ng/L ranged from 77 ± 12 to 110 ± 18%. Method detection limits (MDLs) were as low as 0.040–0.8 ng/L. Extraction and quantitation of total fiproles at a wastewater-receiving wetland yielded concentrations in surface water and pore water ranging from 9.9 ± 4.6 to 18.1 ± 4.6 ng/L and 9.1 ± 3.0 to 12.6 ± 2.1 ng/L, respectively. Detected concentrations were statistically indistinguishable from those determined by conventional, more laborious techniques (p > 0.2 for the three most abundant fiproles). Aside from offering time-averaged sampling capabilities for two phases simultaneously with picogram-per-liter MDLs, the novel methodology eliminates the need for water and sediment transport via in situ solid phase extraction.
机译:摘要:我们设计并评估了一种主动采样设备,该设备使用了一系列据称可导致蜜蜂菌落崩溃的农药作为分析目标。使用低流量,多通道泵将大量水和孔隙水同时采样,以将水输送到一系列固相萃取柱上。使用液相色谱或气相色谱分离分析物,并使用串联质谱(MS / MS)进行分析。在标称浓度为0.1、1和10 ng / L的水中加标的氟虫腈和降解物的回收率从77±12到110±18%。方法检测限(MDL)低至0.040–0.8µng / L。在接收废水的湿地中,总纤维蛋白的提取和定量分别在地表水和孔隙水中的浓度分别为9.9±4.6至18.1±4.6 ng / L和9.1±3.0至12.6±2.1 ng / L。所检测到的浓度与通过常规,更费力的技术所确定的浓度在统计学上没有区别(三个最丰富的鱼腥草的p> 0.2)。除了同时提供两相的平均时间采样能力和每公升皮克MDL之外,该新方法还消除了通过原位固相萃取进行水和沉积物运输的需求。

著录项

  • 作者

  • 作者单位
  • 年度 2016
  • 总页数
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号