Two types of integrative sampling approaches (passive samplers and biomonitors) were tested for their sampling characteristics of selected pollutants. Chemical analysis by gas chromatography with mass spectrometry (GC/MSD) were used to determine the amounts of eight compounds (diuron, γ-HCH, atrazine, irgarol, phenanthrene, dieldrin and two congeners of polychlorinated biphenyls; PCB 52 and PCB 153) in two passive sampling devices (Chemcatcher and Ecoscope) and marine mussels (Mytilus edulis), both had been deployed in Langstone and Portsmouth Harbours, UK. Duiron, irgarol, atrazine and phenanthrene were determined in spot samples of the two deployment sites (Haslar Marina and Port Solent) during field trail. All the compounds except the dieldrin have been detected by Chemcatcher passive samples and mussels. Ecoscope passive samples had the ability to detect diuron and irgarol with lower concentration (1.5 and 22.4 ng L-1, respectively) than detected by Chemcatcher passive samples (1500 and 125 ng device -1) in port Solent after 14 days of the deployment. The study proved that Chemcatcher passive samples and biomonitoring organisms may provide complementary information since, the former samples only the free fraction and the latter both the free and particulate-bound fractions of pollutants in aquatic environments. The Chemcatcher samples has been proved that it can overcome some of the deficiencies of existing devices such as Ecoscope passive samples and to cover a wide range of polarities. It proved also to be the preferred method for assessing the presence of these compounds since, employing mussels had several disadvantages both in sampling efficiency and sample analysis.
机译:测试了两种类型的综合采样方法(被动采样器和生物监测器)对选定污染物的采样特性。使用气相色谱质谱仪(GC / MSD)进行化学分析,确定了以下化合物中8种化合物(敌草隆,γ-六氯环己烷,at去津,依加洛尔,菲,狄氏剂和两种多氯联苯的同系物; PCB 52和PCB 153)的含量。在英国的朗斯通和朴次茅斯港部署了两个被动采样设备(Chemcatcher和Ecoscope)和海洋贻贝(Mytilus edulis)。在野外追踪期间,在两个部署地点(哈斯拉尔码头和索伦特港)的现场样品中确定了Duiron,irgarol,at去津和菲。除狄氏剂外的所有化合物均已通过Chemcatcher被动样品和贻贝检测到。部署14天后,Ecoscope被动样品能够检测到比Solcat港口的Chemcatcher被动样品(1500和125 ng -1 -1)低的浓度(分别为1.5和22.4 ng L-1)的敌草隆和依加洛尔。该研究证明,Chemcatcher被动样品和生物监测生物可以提供互补的信息,因为前者仅采样水生环境中污染物的自由部分,而后者则是污染物的自由部分和结合颗粒的部分。 Chemcatcher样品已被证明可以克服现有设备(如Ecoscope无源样品)的某些缺陷,并能覆盖多种极性。由于使用贻贝在采样效率和样品分析方面都存在多个缺点,因此它也被证明是评估这些化合物存在的首选方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号